Millipore Sigma Vibrant Logo

EZRGRA-90K Rat/Mouse Ghrelin (active) ELISA

View Products on Sigmaaldrich.com
EZRGRA-90K
96-well strip plate  
Retrieving price...
Price could not be retrieved
Minimum Quantity is a multiple of
Maximum Quantity is
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited Availability
Limited Availability
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Replacement Information

      Key Spec Table

      Analytes AvailableSpecies ReactivityKey ApplicationsDetection Methods
      Ghrelin R, MELISAColorimetric Fluorescent
      Description
      Catalogue NumberEZRGRA-90K
      DescriptionRat/Mouse Ghrelin (active) ELISA
      Background InformationCirculating ghrelin is a multifunctional hormone secreted primarily by the stomach. Originally found as an endogenous ligand for the growth hormone secretagogue receptor, it is also an appetite-stimulating hormone in the regulation of energy homeostasis. It consists of 28 amino acids and the n-octanoylation of serine-3 position is necessary for its bioactivity. Long considered a key player in obesity, ghrelin may also play a role in maintaining the balance between insulin and glucose and the development of diabetes. The spike in insulin secretion occurring after eating usually correlates with a dip in ghrelin production. Researchers determined that in rat models of uncontrolled diabetes, food intake still suppressed ghrelin concentrations in the blood, but only approximately half as effectively as when insulin was present.

      Millipore is pleased to offer a new Rat/Mouse Ghrelin (Active) ELISA kit for the quantification of active ghrelin in rat and mouse serum or plasma samples. Each kit is sufficient to measure 39 unknown samples in duplicate.
      References
      Product Information
      Detection methodColorimetric Fluorescent
      HS Code3507 90 29
      Precision, %
      • Inter-assay: Serum: 1-10% Plasma: 1-5%
      • Intra-assay: Serum: 0.3 - 7% Plasma: 1–6%
      Quality LevelMQ200
      Applications
      ApplicationThis Rat/Mouse Ghrelin (active) ELISA is used to measure & quantify Ghrelin levels in Metabolism & Endocrine research.
      Key Applications
      • ELISA
      Application NotesRoom temperature, 3 hour assay, 20 μL sample size (serum or plasma)
      Biological Information
      SpecificityRat/Mouse Ghrelin (Active) - 100%
      Rat/Mouse "Des-Octanoyl" Ghrelin - 0%
      Canine Ghrelin (Active) - 111%
      Porcine Ghrelin (Active) - 98%
      Species Reactivity
      • Rat
      • Mouse
      Analytes Available
      • Ghrelin
      UniProt Number
      Accuracy
      • Serum: 95-98%
      • Plasma: 94-105%
      Physicochemical Information
      Linearity of DilutionPlease contact Technical Service to verify
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Usage Statement
      • For research use only. Not for use in diagnostic procedures.
      Storage and Shipping Information
      Packaging Information
      Material Size96-well strip plate
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      Catalogue Number GTIN
      EZRGRA-90K 04053252475818

      Documentation

      Protocols

      Title
      Protocol: Rat/Mouse Ghrelin (Active)

      Rat/Mouse Ghrelin (active) ELISA MSDS

      Title

      Safety Data Sheet (SDS) 

      References

      Reference overviewPub Med ID
      Ghrelin ameliorates hypoxia-induced pulmonary hypertension via phospho-GSK3{beta}{beta}-catenin signaling in neonatal rats.
      Xu YP, Zhu JJ, Cheng F, Jiang KW, Gu WZ, Shen Z, Wu YD, Liang L, Du LZ
      Journal of molecular endocrinology  47  33-43. Print 2011.  2011

      Show Abstract
      21504941 21504941
      Diet-induced obesity causes ghrelin resistance in arcuate NPY/AgRP neurons.
      Briggs DI, Enriori PJ, Lemus MB, Cowley MA, Andrews ZB
      Endocrinology  151  4745-55. Epub 2010 Sep 8.  2010

      Show Abstract
      20826561 20826561

      Technical Info

      Title
      96 well Template 2 Up
      96 well Template Single
      Quality Control Range Sheet- ARGR-122 and ARGR-222
      Quality Control Ranges: Rat/Mouse Ghrelin (Active) ELISA

      Related Products & Applications

      Related Products

      Catalogue Number Description  
      EZGRA-88K Human Ghrelin (active) ELISA Show Pricing & Availability
      EZRGRT-91K Rat/Mouse Ghrelin (total) ELISA Show Pricing & Availability
      RMHMAG-84K MILLIPLEX MAP Rat Metabolic Hormone Magnetic Bead Panel - Metabolism Multiplex Assay Show Pricing & Availability

      Categories

      Life Science Research > Antibodies and Assays > Immunoassays > Enzyme-linked Immunosorbent Assay (ELISA) > Complete ELISA Kits
      Life Science Research > Protein Detection and Quantification > Immunoassays > Enzyme-linked Immunosorbent Assay (ELISA) > Complete ELISA Kits