Millipore Sigma Vibrant Logo

KZRVA3TTT1 Opticap XLT30 Viresolve NFR 1-1/2 in. TC/TC

KZRVA3TTT1
1  Double Easy-Open bag
Retrieving price...
Price could not be retrieved
Minimum Quantity is a multiple of
Maximum Quantity is
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited Availability
Limited Availability
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Replacement Information
      Description
      Catalogue NumberKZRVA3TTT1
      Trade Name
      • Viresolve®
      DescriptionOpticap XLT30 Viresolve NFR 1-1/2 in. TC/TC
      References
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet38 mm (1-1/2 in.) Sanitary Flange
      Connections, Vent/Drain1/4 in. Hose Barb with double O-ring Seal
      Maximum Differential Pressure, bar (psid)Forward: 5.5 bar (80 psid). Reverse: 3.4 bar (50 psid)
      Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 23 °C
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      T-line/Gauge PortT-line
      Quality LevelMQ400
      Applications
      ApplicationRetrovirus removal
      Key Applications
      • Protein Purification
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaViresolve® NFR
      SterilizationAfter wetting, may be autoclaved for 3 cycles of up to 60 min at 125 °C, using liquid cycle, slow exhaust.
      Physicochemical Information
      Inlet ConnectionSanitary Flange
      Outlet ConnectionSanitary Flange
      Air Diffusion at 23 °C≤48 mL/min @ 3.45 bar (50 psig) in water
      Gravimetric ExtractablesThe extractables level was equal to or less than 105 mg after a 10 minute 1.5 LPM/ft² flush and 24 hours in water at controlled room temperature.
      Hold-up Volume490 mL
      Maximum Inlet Pressure (psig)80 psig
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a Viresolve® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Length86 cm (34 in.)
      Filtration Area1.281 m²
      Inlet to Outlet Width15.2 cm (6.0 in.)
      Process Volume1800 L–3600 L
      Device Size30 in.
      Inlet Connection Diameter1-1/2 in.
      Outlet Connection Diameter1-1/2 in.
      Materials Information
      Chemistry
      • Polyethersulfone (PES)
      Device Material
      • Polypropylene
      Seal MaterialSilicone (SI)
      Support MaterialPolypropylene
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥12 L
      Global Trade Item Number
      Catalogue Number GTIN
      KZRVA3TTT1 04053252604508