Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

105110 Kálium-hexahidroxo-antimonát(V)

105110
Purchase on Sigma-Aldrich

Áttekintés

Replacement Information

Kulcsspecifikációk táblázata

CAS #EC NumberHill FormulaChemical FormulaMolar Mass
12208-13-8235-387-7H₆KO₆SbK[Sb(OH)₆]262.9 g/mol

Products

KatalógusszámCsomagolás Menny./csomag
1051100100 Muanyagpalack 100 g
Description
Catalogue Number105110
SynonymsPotassium antimonate
References
Product Information
CAS number12208-13-8
EC index number051-003-00-9
EC number235-387-7
Hill FormulaH₆KO₆Sb
Chemical formulaK[Sb(OH)₆]
Molar Mass262.9 g/mol
HS Code2841 90 60
Quality LevelMQ300
Applications
Biological Information
Physicochemical Information
pH value7.5 - 9.0 (20 g/l, H₂O, 20 °C)
Bulk density1200 kg/m3
Solubility20 g/l
Dimensions
Materials Information
Toxicological Information
Safety Information according to GHS
Hazard Pictogram(s) Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Statement(s)H302 + H332: Lenyelve vagy belélegezve ártalmas.
H411: Mérgező a vízi élővilágra, hosszan tartó károsodást okoz.
Precautionary Statement(s)P261: Kerülje a por belélegzését.
P264: A használatot követően a bőrt alaposan meg kell mosni.
P271: Kizárólag szabadban vagy jól szellőző helyiségben használható.
P273: Kerülni kell az anyagnak a környezetbe való kijutását.
P301 + P312: LENYELÉS ESETÉN: Rosszullét esetén forduljon TOXIKOLÓGIAI KÖZPONTHOZ/orvoshoz.
P304 + P340 + P312: BELÉLEGZÉS ESETÉN: Az érintett személyt friss levegőre kell vinni, és olyan nyugalmi testhelyzetbe kell helyezni, hogy könnyen tudjon lélegezni. Rosszullét esetén forduljon TOXIKOLÓGIAI KÖZPONTHOZ/orvoshoz.
Signal WordFigyelem
Storage class10 - 13 Egyéb folyadékok és szilárd anyagok
WGKWGK 2 vízszennyező
Disposal15
Heavy metal-containing solutions and solids: container E. Stir Raney nickel (also: Urushibara nickel) in the form of an aqueous suspension into hydrochloric acid (Cat. No. 100312) until dissolved (container E). Neither Raney nickel itself nor any filter residues should be allowed to dry out, otherwise they will spontaneously ignite in air. In this context, heavy metal means any compound of antimony, arsenic, cadmium, chromium(VI), copper, lead, nickel and tin, as well as these subtances in metallic form, if they are classified as hazardous (acc. to AbfallverzeichnisV - Waste Catalogue Ordinance, Appendix 3). Other heavy metals should be collected separately.
Safety Information
Categories of dangeregészséget károsító hatású, környezetre káros
Product Usage Statements
Storage and Shipping Information
Storage+2°C és +30°C között tárolandó.
Packaging Information
Transport Information
Declaration (railroad and road) ADR, RIDUN 3077 , 9, III
Declaration (transport by air) IATA-DGRUN 3077 , 9, III
Declaration (transport by sea) IMDG-CodeUN 3077 , 9, III, Marine Pollutant: P
Supplemental Information
Specifications
Identitypasses test
Assay (iodometric, calculated on calcined substance)≥ 99.0 %
Free alkali (as KOH)≤ 0.1 %
Na (Sodium)≤ 0.2 %
Global Trade Item Number
Katalógusszám GTIN
1051100100 04022536061252