Millipore Sigma Vibrant Logo

CZRV72TP1 Viresolve NFR Cartridge Filter 20 in. Code 7

View Products on Sigmaaldrich.com
CZRV72TP1
1  Double Easy-Open bag
正在检索价格......
无法检索价格。
最小订购数量为倍数
Maximum Quantity is
以订单确认为准 更多信息
您节约了 ()。
 
Request Pricing
目前缺货
目前缺货
有货 
停产
少量现货
供货情况有待确认
    其余:另行通知
      其余:另行通知
      另行通知
      联系客户服务
      Contact Customer Service

       

      联系客户服务

      概述

      Replacement Information
      Description
      Catalogue NumberCZRV72TP1
      Trade Name
      • Viresolve®
      DescriptionViresolve NFR Cartridge Filter 20 in. Code 7
      References
      Product Information
      Device ConfigurationCartridge
      Maximum Differential Pressure, bar (psid)Forward: 5.5 bar (80 psid) @ 25 °C. Reverse: 3.4 bar (50 psid) @ 25 °C
      Cartridge CodeCode 7
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Quality LevelMQ400
      Applications
      ApplicationRetrovirus removal
      Key Applications
      • Protein Purification
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaViresolve® NFR
      SterilizationAfter wetting, may be autoclaved for 3 cycles of up to 60 min at 125 °C,
      using liquid cycle, slow exhaust.
      Physicochemical Information
      Air Diffusion at 23 °C≤32 mL/min @ 3.45 bar (50 psig) in water
      Gravimetric ExtractablesThe extractables level was equal to or less than 35 mg per 10-inch cartridge after a 10 minute 1.5 LPM/ft² flush and 24 hours in water at controlled room temperature.
      Hold-up Volume325 mL
      Non-Fiber ReleasingThis product was manufactured with a Viresolve® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length20 in. (50 cm)
      Filtration Area0.854 m²
      Process Volume1200 L–2400 L
      Device Size20 in.
      Materials Information
      Chemistry
      • Polyethersulfone (PES)
      Device Material
      • Polypropylene
      Seal MaterialSilicone (SI)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥8 L
      Global Trade Item Number
      产品目录编号 GTIN
      CZRV72TP1 04053252571343