Pellicon® XL 50 Ultrafiltration Cassettes

True linear scalability with UF membranes with the same flow path and channel height as larger Pellicon® 2 cassettes. The Pellicon XL 50 allows process development and scaling studies.

概述

规格

订货信息

继续
Biomax® Polyethersulfone清除排序和过滤条件 Show Filter
产品目录编号过滤器代码NMWL
PXB005A50Biomax 5 5 kDa 显示价格及库存情况
PXB008A50Biomax 8 8 kDa 显示价格及库存情况
PXB010A50Biomax 10 10 kDa 显示价格及库存情况
PXB030A50Biomax 30 30 kDa 显示价格及库存情况
PXB050A50Biomax 50 50 kDa 显示价格及库存情况
PXB100C50Biomax 100 100 kDa 显示价格及库存情况
PXB300C50Biomax 300 300 kDa 显示价格及库存情况
PXB500C50Biomax 500 500 kDa 显示价格及库存情况
PXB01MC50Biomax 1000 1000 kDa 显示价格及库存情况

返回顶部

Ultracel® Regenerated Cellulose清除排序和过滤条件 Show Filter
产品目录编号过滤器代码NMWL
PXC005C50PLCCC 5 kDa 显示价格及库存情况
PXC010C50PLCGC 10 kDa 显示价格及库存情况
PXC030C50PLCTK 30 kDa 显示价格及库存情况
PXC300C50PLCMK 300 kDa 显示价格及库存情况
PXC01MC50PLCXK 1000 kDa 显示价格及库存情况
PXC100C50PLCHK 100 kDa 显示价格及库存情况

返回顶部

Accessories清除排序和过滤条件 Show Filter
产品目录编号描述
XXPXLFTKTFittings Adapters and Tubing 显示价格及库存情况
XXPXLSTNDStand for Pellicon 显示价格及库存情况
XX42RES01Reservoir, 500 mL, for LabScale 显示价格及库存情况
XXPXLGAGEGauge 0-60 psi and Connection Fittings 显示价格及库存情况

Each Pellicon® XL device is packaged one per box

返回顶部

Documentation

参考

参考概述
Scaling Up with Tangenital Flow Filtration
Campbell, Melissa; Coons, Elizabeth
GEN; v. 21, no. 16; Sept. 15, 2001, p. 60  2001

Linear Scale Ultrafiltration
van Reis, Robert, Elizabeth M. Goodrich, Christine L. Yson, Leah N. Frautschy, Stephen Dzengeleski, and Herb Lutz
Biotechnology & Bioengineering (September 1997): 737-746.  1997

Clean-Water Permeability as a Determinant of Cleaning Efficacy in Tangential-Flow Filtration Systems
Michaels, Stephen L.; RP016
RP016  1994

Validation of Tangential Flow Filtration (TFF) Systems
Michaels, Stephen L.
Journal of Parenteral Science and Technology (Sept/Oct 1991).  1991

问与答

问题回答
What is the sample volume range for the Pellicon II Mini system?The Pellicon II Mini system is capable of volumes in the approximate range of 1- 50 L concentrating down to 100 mL. More or less volume can be processed depending on the individual needs of the operation, ie. process time, sensitivity of product, etc.
What is the part number for the Gauge Kit that is used with the Pellicon XL?Gauge Kit for Pellicon XL Device (0-60 psi):
Part number XXPXLGAGE, 1 per kit. Includes an inlet pressure gauge and t-fitting. This gauge is recommended when the Pellicon is used in the absence of a Labscale TFF system in order to ensure that the pressure on the tubing is known and not allowed to exceed it's recommended maximum.
Can I use TFF systems to separate two proteins based on a significant difference in their respective molecular weights?As a general rule ultrafiltration does not provide high efficiency separations of protein mixtures. However, it may be possible to effect this type of separation between two proteins that have at least 10 X difference in molecular weight and if there is an ultrafiltration membrane available with a NMWL rating between the molecular weight of the two proteins. These separations are also generally more successful with dilute protein solutions and if run at low pressure.

相关产品和应用

产品族

相关产品,按下列排序: Application Facete

相关产品,按下列排序: Brand Facete

种类

Biopharmaceutical Manufacturing > Downstream Processing > Ultrafiltration