      Replacement Information
      Description
      Catalogue NumberKGW1A3THH1
      Trade Name
      • Opticap®
      DescriptionOpticap® XLT30 Polysep® II 1.0/0.2/0.1 µm 5/8 in. HB
      References
      Product Information
      FormatTriple Layer
      Device ConfigurationCapsule
      Connections, Inlet/Outlet16 mm (5/8 in.) Hose Barb
      Housing MaterialPolypropylene (PP)
      Maximum Differential Pressure, bar (psid)3.5 bar (50 psid) @ 25 °C
      Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Prefilter MaterialBorosilicate Glass Fiber (BGF)
      T-line/Gauge PortT-line
      Quality LevelMQ400
      Applications
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaPolysep™ II
      Sterilization3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
      Physicochemical Information
      Pore Size1.0 / 0.2 / 0.1 µm
      Inlet ConnectionHose Barb
      Outlet ConnectionHose Barb
      Gravimetric ExtractablesThe extractables level was equal to or less than 435 mg per capsule after a 15 L flush and 24 hours in water at controlled room temperature.
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Inlet Pressure (psig)80 psig
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length30 in. (75 cm)
      Length87.1 cm (34.3 in.)
      Filtration Area1.26 m²
      Inlet to Outlet Width19.8 cm (7.8 in.)
      Device Size30 in.
      Inlet Connection Diameter5/8 in.
      Nominal Pore Size1.0 / 0.2 / 0.1 µm
      Outlet Connection Diameter5/8 in.
      Materials Information
      Chemistry
      • Mixed Cellulose Esters (MCE)
      Device Material
      • Polypropylene
      Seal MaterialSilicone (SI)
      Support MaterialPolypropylene
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L
      Global Trade Item Number
      产品目录编号 GTIN
      KGW1A3THH1 04053252253928

      Documentation

      Opticap® XLT30 Polysep® II 1.0/0.2/0.1 µm 5/8 in. HB MSDS

      职位

      物料安全数据表 (MSDS) 

      质量证书

      标题
      Opticap XLT 30 Capsule Polysep II Media C7HA24571
      Opticap XLT 30 Capsule Polysep II Media C8BA13347
      Opticap XLT 30 Capsule Polysep II Media C0AB97761
      Opticap XLT 30 Capsule Polysep II Media C0EB58692
      Opticap XLT 30 Capsule Polysep II Media C1HB21295
      Opticap XLT 30 Capsule Polysep II Media -C8NA16093
      Opticap XLT 30 Capsule Polysep II Media C0SB33754
      Opticap XLT 30 Capsule Polysep II Media C3MB53492
      Opticap XLT 30 Capsule Polysep II Media C4DB01518
      Opticap XLT 30 Capsule Polysep II Media C7EA15331

      技术信息

      标题
      Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters

      用户指南

      标题
      Opticap® XL Capsules and Opticap® XLT Capsules