      Catalogue NumberKGW2A05FF1
      Trade Name
      • Opticap®
      DescriptionOpticap® XL5 Polysep® II 1.0/1.2 µm 3/4 in. TC/TC
      Product Information
      FormatDouble Layer
      Device ConfigurationCapsule
      Connections, Inlet/Outlet19 mm (3/4 in.) Sanitary Flange
      Housing MaterialPolypropylene (PP)
      Maximum Differential Pressure, bar (psid)3.5 bar (50 psid) @ 25 °C
      Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Prefilter MaterialBorosilicate Glass Fiber (BGF)
      Quality LevelMQ400
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaPolysep™ II
      Sterilization3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
      Physicochemical Information
      Pore Size1.0 / 1.2 µm
      Inlet ConnectionSanitary Flange
      Outlet ConnectionSanitary Flange
      Gravimetric ExtractablesThe extractables level was equal to or less than 61 mg per capsule after a 5 L flush and 24 hours in water at controlled room temperature.
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Inlet Pressure (psig)80 psig
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length5 in. (12.5 cm)
      Length21.6 cm (8.5 in.)
      Diameter14.5 cm (5.7 in.)
      Filtration Area0.19 m²
      Inlet to Outlet Width21.6 cm (8.5 in.)
      Device Size5 in.
      Inlet Connection Diameter3/4 in.
      Nominal Pore Size1.0 / 1.2 µm
      Outlet Connection Diameter3/4 in.
      Materials Information
      Chemistry
      • Mixed Cellulose Esters (MCE)
      Device Material
      • Polypropylene
      Seal MaterialSilicone (SI)
      Support MaterialPolypropylene
      Vent Cap MaterialPolypropylene (PP)
      Packaging Information
      Material Size1
      Material PackageDouble Easy-Open bag
      Specifications