Millipore Sigma Vibrant Logo

KHGEG10HH1 Opticap® Gamma Compatible XL 10 Millipore Express® SHC 0.5/0.2 µm 9/16 in. HB/HB

View Products on Sigmaaldrich.com
KHGEG10HH1
1  Double Easy-Open bag
正在检索价格......
无法检索价格。
最小订购数量为倍数
Maximum Quantity is
以订单确认为准 更多信息
您节约了 ()。
 
Request Pricing
目前缺货
目前缺货
有货 
停产
少量现货
供货情况有待确认
    其余:另行通知
      其余:另行通知
      另行通知
      联系客户服务
      Contact Customer Service

       

      联系客户服务

      概述

      Replacement Information
      Description
      Catalogue NumberKHGEG10HH1
      Trade Name
      • Millipore Express®
      DescriptionOpticap® Gamma Compatible XL 10 Millipore Express® SHC 0.5/0.2 µm 9/16 in. HB/HB
      References
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet14 mm (9/16 in.) Hose Barb
      Connections, Vent/Drain1/4 in. Hose Barb with double O-ring seal
      Housing MaterialPolypropylene (PP)
      Maximum Differential Pressure, bar (psid)Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
      Maximum Inlet Pressure, bar (psi)6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Quality LevelMQ400
      Applications
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaMillipore Express® SHC
      SterilityNon-sterile, Gamma compatible
      SterilizationGamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.5 / 0.2 µm
      Inlet ConnectionHose Barb
      Outlet ConnectionHose Barb
      Air Diffusion at 23 °C≤31.2 mL/min @ 2.8 bar (40 psig) in water
      Bubble Point at 23 °C≥4000 mbar (58 psig) air with water
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Inlet Pressure (psig)80 psig
      Maximum Differential Pressure80 psi (5.5 bar) continuous
      100 psi (6.9 bar) intermittent
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      TOC/ConductivityAfter sterilization and a controlled water flush of 21 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length10 in. (25 cm)
      Length33.5 cm (13.2 in.)
      Diameter10.7 cm (4.2 in.)
      Filtration Area0.54 m²
      Inlet to Outlet Width33.5 cm (13.2 in.)
      Device Size10 in.
      Inlet Connection Diameter9/16 in.
      Outlet Connection Diameter9/16 in.
      Materials Information
      Chemistry
      • Polyethersulfone (PES)
      Device Material
      • Polypropylene/Polysulfone
      Seal MaterialSilicone (SI)
      Support MaterialPolyester
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L
      Global Trade Item Number
      产品目录编号 GTIN
      KHGEG10HH1 04053252565007

      Documentation

      Material Qualification Dossier

      标题版本
      1.0

      Quality Management Dossier (Open Access)

      Title

      Operational Excellence Dossier

      Title

      质量证书

      标题
      Opticap XL 10 Capsule Millipore Express SHC Membrane C7PA84002
      Opticap XL 10 Capsule Millipore Express SHC Membrane C7SA09602
      Opticap XL 10 Capsule Millipore Express SHC Membrane C0DB60694
      Opticap XL 10 Capsule Millipore Express SHC Membrane C0JB91973
      Opticap XL 10 Capsule Millipore Express SHC Membrane C0KB03236
      Opticap XL 10 Capsule Millipore Express SHC Membrane C0NB31600
      Opticap XL 10 Capsule Millipore Express SHC Membrane C1AB74635
      Opticap XL 10 Capsule Millipore Express SHC Membrane C1DB90916
      Opticap XL 10 Capsule Millipore Express SHC Membrane C1PB51525
      Opticap XL 10 Capsule Millipore Express SHC Membrane C2BB26140

      技术信息

      标题
      Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters
      Extended bacterial retention testing of Millipore Express® 0.2 μm filters in a continuous flow system
      Simplified, efficient sizing of sterilizing-grade normal flow filters for buffer solutions

      数据表

      标题
      Millipore Express®SHC Hydrophilic Filters

      用户指南

      标题
      Opticap® XL Capsules and Opticap® XLT Capsules
      User Guide - Filters with Millipore Express®Membrane
      Vmax Constant Pressure