Millipore Sigma Vibrant Logo

KVVLG04HH3 Opticap® Gamma Compatible Sterilizing Grade XL4 Durapore® 0.1 µm 9/16 in. HB/HB

View Products on Sigmaaldrich.com
KVVLG04HH3
3  Double Easy-Open bag
正在检索价格......
无法检索价格。
最小订购数量为倍数
Maximum Quantity is
以订单确认为准 更多信息
您节约了 ()。
 
Request Pricing
目前缺货
目前缺货
有货 
停产
少量现货
供货情况有待确认
    其余:另行通知
      其余:另行通知
      另行通知
      联系客户服务
      Contact Customer Service

       

      联系客户服务

      概述

      Replacement Information
      Description
      Catalogue NumberKVVLG04HH3
      Trade Name
      • Opticap®
      DescriptionOpticap® Gamma Compatible Sterilizing Grade XL4 Durapore® 0.1 µm 9/16 in. HB/HB
      References
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet14 mm (9/16 in.) Hose Barb
      Connections, Vent/Drain1/4 in. Hose Barb with double O-ring Seal
      Housing MaterialPolypropylene (PP)
      Maximum Differential Pressure, bar (psid)Forward: 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.8 bar (40 psid) @ 25 °C, intermittent
      Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 23 °C; 2.8 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Quality LevelMQ400
      Applications
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaDurapore®
      SterilityNon-sterile, Gamma compatible
      Sterilization3 autoclave cycles of 60 min @ 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.1 µm
      Inlet ConnectionHose Barb
      Outlet ConnectionHose Barb
      Air Diffusion at 23 °C≤5.7 mL/min @ 3.9 bar (56 psig) in water
      Bubble Point at 23 °C≥4830 mbar (70 psig) air with water
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Inlet Pressure (psig)80 psig
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      TOC/ConductivityAfter sterilization and a controlled water flush, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 ºC.
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length4 in. (10 cm)
      Length17.0 cm (6.7 in.)
      Diameter6.1 cm (2.4 in.)
      Filtration Area0.18 m²
      Device Size4 in.
      Inlet Connection Diameter9/16 in.
      Outlet Connection Diameter9/16 in.
      Materials Information
      Chemistry
      • Polyvinylidene Fluoride (PVDF)
      Device Material
      • Gamma-stable polypropylene
      Seal MaterialLead O-ring: Silicone-coated EPDM, Outer O-ring: Silicone
      Support MaterialPolyester
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size3
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥500 mL
      Global Trade Item Number
      产品目录编号 GTIN
      KVVLG04HH3 04053252377051

      Documentation

      Material Qualification Dossier

      标题版本
      2.0

      Operational Excellence Dossier

      Title

      质量证书

      标题
      OPTICAP XL 4 Capsule Durapore Membrane C3BB87791
      Opticap XL 4 Capsule Durapore Membrane C7MA56391
      Opticap XL 4 Capsule Durapore Membrane C7PA03351
      Opticap XL 4 Capsule Durapore Membrane C0MB15071Z
      Opticap XL 4 Capsule Durapore Membrane C0NB15073Z
      Opticap XL 4 Capsule Durapore Membrane C0NB15077Z
      Opticap XL 4 Capsule Durapore Membrane C0SB26108Z
      Opticap XL 4 Capsule Durapore Membrane C1BB07754Z
      Opticap XL 4 Capsule Durapore Membrane C1EB01515Z
      Opticap XL 4 Capsule Durapore Membrane C7DA94276

      技术信息

      标题
      Establishing Product Specific Bubble Point Specifications For Sterilizing-Grade Filters
      Simplified, efficient sizing of sterilizing-grade normal flow filters for buffer solutions

      数据表

      标题
      Durapore® Family Guide

      用户指南

      标题
      Opticap® XL Capsules and Opticap® XLT Capsules

      相关产品和应用

      产品族

      相关产品,按下列排序: Brand Facete

      种类

      Biopharmaceutical Manufacturing > Downstream Processing > Sterile Filtration > Sterile Liquid > Durapore