Millipore Sigma Vibrant Logo

NAC-A150/25 NovAseptic Connector, According to PED, Tube Standard ASTM A270

NAC-A150/25
1  All open ends on the NovAseptic Connector are protected with plastic covers on delivery. The NovAseptic Connector is pre-assembled and packaged in a closed box.
正在检索价格......
无法检索价格。
最小订购数量为倍数
Maximum Quantity is
以订单确认为准 更多信息
您节约了 ()。
 
Request Pricing
目前缺货
目前缺货
有货 
停产
少量现货
供货情况有待确认
    其余:另行通知
      其余:另行通知
      另行通知
      联系客户服务
      Contact Customer Service

       

      联系客户服务

      概述

      Replacement Information
      Description
      Catalogue NumberNAC-A150/25
      Trade Name
      • NovaSeptic
      DescriptionNovAseptic Connector, According to PED, Tube Standard ASTM A270
      References
      Product Information
      Surface Finish, WettedManually polished; Ra ≤1.6 μm (63 μin)
      Operating Temperature Range-80 to 200 °C
      Quality LevelSP2
      Applications
      Application NotesThe applied gasket (not included) may have different design temperature and/or pressure limits than the NovAseptic Connector. The weakest component in the assembled product determines the maximum design temperature and pressure limits.
      Biological Information
      Physicochemical Information
      Operating Pressure Range-1 to –7 bar
      Dimensions
      DimensionsFor information about the dimensions of this product please refer to the Product Specification Sheet.
      Weight0.8 kg (1.8 lb.)
      Materials Information
      Device Material
      • Welding Flange: Stainless Steel 316L (ASME SA-479)/EN 1.4435 (EN 10272)
      • Locking Ring: Stainless Steel 316L (ASME 479)/EN 1.4404 (EN 10272)
      • Bolt and Nut: Stainless Steel EN 1.4401/ EN 1.4301 (EN 10269)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Regulatory ConformanceThe NovAseptic Connector does comply for Europe with the relevant requirements in Annex I, Essential Safety Requirement in PED Directive 97/23/EC and AD 2000. The equipment has been examined with respect to the relevant parts for design examination procedure of conformity assessment as described in Module B in the AFS 1999:4 (PED 97/23/EC), by Notified Body.
      Storage and Shipping Information
      Packaging Information
      Material Size1
      Material PackageAll open ends on the NovAseptic Connector are protected with plastic covers on delivery. The NovAseptic Connector is pre-assembled and packaged in a closed box.
      Transport Information
      Supplemental Information
      Specifications
      Connector TypeFlush mounted
      Global Trade Item Number
      产品目录编号 GTIN
      NAC-A150/25 04053252247194