UFC910024 MilliporeAmicon Ultra-15,PLHK Ultracel-PL 超滤膜,100 kDa
Ultracel-100 regenerated cellulose membrane, 15 mL sample volume
More>> Ultracel-100 regenerated cellulose membrane, 15 mL sample volume Less<<Amicon Ultra-15,PLHK Ultracel-PL 超滤膜,100 kDa MSDS (material safety data sheet) or SDS, CoA and CoQ, dossiers, brochures and other available documents.
Recommended Products
概述
Replacement Information |
---|
重要规格表
Key Applications | NMWL | 体积 | 最低最终浓缩液体积 |
---|---|---|---|
蛋白提取, 蛋白纯化 | 100 KDa | 15 mL | 200 µL |
参考 |
---|
产品信息 | |
---|---|
过滤器代码 | PLHK |
色码 | 透明,带有粉色盖 |
过滤器类型 | 超滤 |
NMWL | 100 KDa |
Quality Level | MQ400 |
应用 | |
---|---|
应用 | Ultracel-100 regenerated cellulose membrane, 15 mL sample volume |
主要应用 |
|
应用说明 | 甩平转子:4,000 x g; 固定角度转子 (35°):5,000 x g |
生物信息 | |
---|---|
无菌性 | 非无菌 |
理化信息 | |
---|---|
离心应用 | 蛋白浓缩和脱盐 |
尺寸 | |
---|---|
长度 | 12.1 cm (4.807 in.) |
直径 | 2.97 cm |
过滤面积 | 7.6 cm² |
最低最终浓缩液体积 | 200 µL |
体积 | 15 mL |
材料信息 | |
---|---|
化学 |
|
装置材料 |
|
支撑材料 | Regenerated cellulose |
毒性学信息 |
---|
GHS安全信息 |
---|
安全信息 |
---|
产品使用声明 |
---|
储存和货运信息 |
---|
包装信息 | |
---|---|
数量 | 24 |
运输信息 |
---|
补充信息 |
---|
规格 |
---|
Global Trade Item Number | |
---|---|
产品目录编号 | GTIN |
UFC910024 | 04053252317439 |
Documentation
参考
参考概述 | 公共医疗ID |
---|---|
Specific Lipids Modulate the Transporter Associated with Antigen Processing (TAP). Schölz, Christian, et al. J. Biol. Chem., 286: 13346-56 (2011) 2011 显示摘要 | 21357424 |
质量证书
标题 |
---|
UFC910024 - 0000241948 |
小册子
标题 |
---|
REFINE PROTEIN PREPARATION. Tools for better protein analysis |
问与答
问题 | 回答 | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Amicon Ultra units are offered in what volumes? | Amicon Ultra units are available in 0.5 mL, 4mL & 15ml volumes. | ||||||||||||
What is the recommended rotor for Amicon Ultra units? | Any rotor capable of accommodating 22.7 cm in diameter and 124 mm length centrifuge tubes for the Amicon Ultra-4 and 35 mm in diameter and 121 mm in length for the Amicon Ultra-15 can be used for Amicon Ultra units. | ||||||||||||
How should I select the appropriate Molecular Weight Cutoff (MWCO) for Amicon Ultra? | Select a Molecular Weight Cutoff that is 2x smaller that the Molecular Weight (MW) of the solute of interest. | ||||||||||||
Which membranes are available in Amicon Ultra units? | Amicon Ultra units are only available with Ultracel regenerated cellulose material. This high recovery/low binding membrane is offered in 3,000, 10,000, 30,000, 50,000 & 100,000 MWCO. | ||||||||||||
Can the Amicon Ultra be spun to dryness? | No, the Amicon Ultra has a built in deadstop. | ||||||||||||
Can the Amicon Ultra be used with nucleic acids? | Yes, Amicon Ultra units have been evaluated for use with Genomic and PCR fragments. The 30 kDa MWCO provides the best balance between recovery and spin time. Protocols related to Genomic and PCR fragments can be found in the user guide. | ||||||||||||
What is the maximum sample volume for Amicon Ultra? |
|
||||||||||||
What is the chemical compatibility of Amicon Ultra? | Amicon Ultra units are intended for use with biological fluids and aqueous solutions. Please refer to the user guide, catalogue, or contact Technical Support. | ||||||||||||
Can Amicon Ultra units be sterilized with ethanol? | Amicon Ultra is compatible with 70% Ethanol, but we have not done any studies to test for sterilization. | ||||||||||||
Do you have any centrifugal filter units that are pyrogen free? | We do not have any centrifugals devices that we claim are pyrogen free. Even the sterile devices could contain pyrogens. |
用户指南
标题 |
---|
Amicon® Ultra-15 Centrifugal Filter Devices Non IVD User guide |