Millipore Sigma Vibrant Logo

MPGL06CF3 Millipak®-60 Filling Machine Filter Unit 0.22 µm 3/4 in. TC/TC

View Products on Sigmaaldrich.com
MPGL06CF3
3  Double Easy-Open bag
Price could not be retrieved
Minimum Quantity is a multiple of
Maximum Quantity is
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Limited Availability
Limited Availability
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Description
      Catalogue NumberMPGL06CF3
      Trade Name
      • Millipak®
      DescriptionMillipak®-60 Filling Machine Filter Unit 0.22 µm 3/4 in. TC/TC
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet19 mm (3/4 in.) Sanitary Flange
      Maximum Differential Pressure, bar (psid)Forward: 4.1 bar (60 psid) @ 25 °C; 1.7 bar (25 psid) @ 80 °C; 0.35 bar (5 psid) @ 123 °C; Reverse: 0.7 bar (10 psid) @ 25 °C
      Maximum Inlet Pressure, bar (psi)5.2 bar (75 psi) @ 25 °C
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Stacked Discs60 discs
      Quality LevelMQ400
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaDurapore®
      SterilityOther
      Sterilization3 autoclave cycles of 90 min @ 123°C; not in-line steam sterilizable
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.22 µm
      Inlet ConnectionSanitary Flange
      Outlet ConnectionSanitary Flange
      Bubble Point at 23 °C≥3450 mbar (50 psig) air with water
      Flow Rate7.6 L/min @ 2.9 bar ΔP
      Gravimetric ExtractablesThe extractables level was equal to or less than 2 mg per device after 24 hours in water at controlled room temperature.
      Non-Fiber ReleasingThis product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Filtration Area300 cm²
      Process Volume30 L
      Inlet Connection Diameter3/4 in.
      Outlet Connection Diameter3/4 in.
      Materials Information
      Chemistry
      • Polyvinylidene Fluoride (PVDF)
      Device Material
      • Polycarbonate
      Support MaterialPolycarbonate
      Vent Cap MaterialPolyvinylidene fluoride (PVDF)
      Packaging Information
      Material Size3
      Material PackageDouble Easy-Open bag
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥200 mL
      Global Trade Item Number
      Catalogue Number GTIN
      MPGL06CF3 04053252655180