Millipore Sigma Vibrant Logo

Ensayos con microesferas

MultiScreenHTS filter plates have been specifically developed for compatibility with the solvents needed for combinatorial chemistry bead cleavage steps.

Descripción

Especificaciones

Información para pedidos

Ir
Placas de filtración MultiScreenHTS con membrana hidrófila Durapore de PVDFBorrar Clasificación y Filtrado Show Filter
Número de referenciaDescripciónMaterial del dispositivoTamaño de poroEsterilidadTamaño de envase
MSDVN6550MultiScreenHTS DV; 0,65 µm, transparente, no estéril Estireno 0.65 µm No estéril 50 Precios y disponibilidad
MSBVN1250MultiScreenHTS BV; 1,2 µm, transparente, no estéril Estireno 1.2 µm No estéril 50 Precios y disponibilidad

Volver al principio

Placas de filtración MultiScreen Solvinert con membrana hidrófila de PTFEBorrar Clasificación y Filtrado Show Filter
Número de referenciaDescripciónMaterial del dispositivoTamaño de poroTamaño de envase
MSRLN0410MultiScreen Solvinert, hidrófilo, PTFE; 0,45 µm, transparente, no estéril Copolímero de poliolefina 0.45 µm 10 Precios y disponibilidad

Volver al principio

AccessoriesBorrar Clasificación y Filtrado Show Filter
Número de referenciaDescripciónTamaño de envase
MSVMHTS00Colector de vacío MultiScreenHTS 1 Precios y disponibilidad
WP6111560Bomba de servicio químico, 115 V/60 Hz 1 Precios y disponibilidad
WP6122050Bomba de servicio químico, 220 V/50 Hz 1 Precios y disponibilidad
WP6110060Bomba de servicio químico, 100 V/50–60 Hz 1 Precios y disponibilidad
MACL09645Cargador de columnas MultiScreen, 45 µl, negro, aluminio, no estéril 1 Precios y disponibilidad
MACL0SC03Enrasador del cargador de columnas MultiScreen 3 Precios y disponibilidad
MSCPNPS00Placa de recogida de 96 pocillos, transparente, no estéril 100 Precios y disponibilidad

Los cargadores de columnas se utilizan para cargar el medio cromatográfico para las separaciones en columna.

Volver al principio

Documentation

Referencias bibliográficas

Visión general referenciasAplicación
Kinetics and isotype profile of antibody responses in rhesus macaques induced following vaccination with HPV 6, 11, 16 and 18 L1-virus-like particles formulated with or without Merck aluminum adjuvant
Wanda Ruiz, William McClements, Kathrin Jansen, and Mark esser
Journal of Immune Based Therapies and Vaccines 2005, 3:2  2004

Bead-based Assays
Use of ADME screening to conserve resources in drug discovery and development
Weiss, A. and Joseph Machamer
American Biotechnology Laboratory, January 2004: 16-17  2004

Screening for pharma gold: Researchers are using membrane technologies for high-throughput ADME analysis
Lynch, John,Modern Drug Discovery, January 2004: 27-28
Modern Drug Discovery, January 2004: 27-28  2004

Scintillation proximity assay of inositol phosphates in cell extracts: High-throughput measurement of G-protein-coupled receptor activation
Philip E. Brandish, Lorraine A. Hill, Wei Zheng and Edward M. Scolnick
Analytical Biochemistry 313 (2): 311-318  2003

Bead-based Assays
Functional roles of conserved transmembrane prolines in the human VPAC1 receptor.
Sanne Moller Knudsen, Jeppe Wegener Tams and Jan Fahrenkrug; Journal of Biochemical and Biophysical Methods 40 (3): 113-117
Journal of Biochemical and Biophysical Methods 40 (3): 113-117  2001

Bead-based Assays
A high-throughput assay for rat liver Golgi and Saccharomyces cerevisiae-expressed murine CMP-N-acetylneuraminic acid transport proteins
Tiralongo J; Abo S; Danylec B; Gerardy Schahn R; vonItzstein M
Analytical Biochemistry 2000 , v285, n1, p21-32  1999

Bead-based Assays
Designing new metal affinity peptides by random mutagenesis of a natural metal-binding site.
Markus M. Enzelberger, Stefan Minning and Rolf D. Schmid
Journal of Chromatography A 898 (1): 83-94  1999

Bead-based Assays
Quantification of telomerase activity by direct scintillation counting.
Sonja Kazmer, Keh-Ming Pan and Lyubomir Vassilev
Journal of Biochemical and Biophysical Methods 40 (3): 113-117  1998

Bead-based Assays
Microplate Chromatography Assay for Acety1-CoA: Lysoplatelet-Activating Factor Acetyltransferase1
Kume, K., Waga, I., Shimizu, T.
Analytical Biochemistry 246:, 118-122  1997

Bead-based Assays
Evaluation of Islet Cell Antigen (ICA)512/IA-2 Autoantibody Radioassays Using Overlapping ICA512/IA-2 Constructs
Kawaski, E., Yu, L., Gianani, R., Verge, C.F., Babu, S., Bonifacio, E., Eisenbarth, G.S.
Journal of Clinical Endocrinology & Metabolism 82:2, 375-380  1997

Bead-based Assays

Preguntas frecuentes

PreguntaRespuesta
What is the well depth and maximum volume capacity of a MultiScreen plate?The well depth of a 96 well MultiScreen plate is 1.245 cm. The well depth for a 384 well MultiScreen plate is 1.2 cm. The maximum working volume of a 96 well plate is 300 ul. The maximum working volume for a 384 well plate is 100 ul.