      Overview

      Key Spec Table

      Key Applications
      WB
      Description
      Catalogue Number2500
      Brand Family Chemicon®
      Trade Name
      • ReBlot
      • Chemicon
      DescriptionReBlot Plus Kit
      OverviewWestern blotting is a commonly used technique for studying protein function and localization. Typically, protein samples are electrophoresed on SDS-PAGE and transferred to a membrane such as nitrocellulose or nylon, where they are probed with specific antibodies. Unlike nucleic acid based technologies, which allow reuse of Southern and Northern blots, it has been difficult to reuse Western blots.

      Stripping and re-probing of Western blots offers several advantages:

      1) Conservation of samples that are expensive or available only in limited quantities,

      2) Analysis of a given blot using several different antibodies, e.g. subtype- or isoform-specific antibodies,

      3) Re-analysis of anomalous results and confirmation with the same or a different antibody,

      4) Correcting errors in incubation with the wrong antibody,

      5) Cost savings in reagents and time by reusing the same blot.

      While antigen and antibody-based immunoaffinity matrices, such as Sepharose™ conjugates, have been reused many times without compromising antigen-antibody reactivity, the need for pH extremes and chaotropic agents has precluded the application of these methods to Western blotting.

      The MILLIPORE Re-Blot Plus Western Blot Recycling Kit contains specially formulated solutions that quickly and effectively remove antibodies from Western blots without significantly affecting the immobilized proteins.

      Advantages of the Re-Blot Plus Western Blot Recycling Kit include:

      ·*No pungent-smelling b-mercaptoethanol is contained in the Antibody Stripping Solution.

      ·*Antibody stripping is done at room temperature. No heating of blots is required.

      ·*Blots can be stripped of antibodies in approximately 15 minutes at room temperature.

      ·*Blots may be reused in 25 minutes.
      Materials Required but Not Delivered· Standard Blot or blot strips, on nitrocellulose or PVDF/nylon membrane.

      · Blocking Solutions.

      · Plastic Wrap, such as Saran Wrap, for storage of blots that will not be re-probed immediately.

      · Distilled Water, for reagent dilution.

      · Plastic Trays for incubation of blots or blot strips in stripping, washing and blocking solutions.

      · Positive and Negative Stripping Controls. It is recommended that one new strip (not subjected to stripping solution) be included for comparison purposes.
      Product Information
      Components
      • Mild Antibody Stripping Solution (10x) - (1 container, 50 mL).
      • Strong Antibody Stripping Solution (10x) - (1 container, 50 mL).
      Detection methodChemiluminescence
      Applications
      Key Applications
      • Western Blotting
      Application NotesThe MILLIPORE Re-Blot Plus Western Blot Recycling Kit is effective for removal of antibodies from Western blots that have been developed with chemiluminescence or radioactive iodine or other isotopes. It is not recommended for stripping colorimetric substrates (TMB, DAB, 4-chloronapthol, etc.), as it is not possible to effectively remove substrates that precipitate at the reaction site.

      The Re-Blot Plus Western Blot Recycling Kit should be used only for qualitative purposes until it has been established by comparative blot analysis that stripping does not quantitatively affect a given antigen.

      This product is for research use only; not for diagnostic or in vivo use.
      Product Usage Statements
      Usage Statement
      • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
      Storage and Shipping Information
      Storage ConditionsKit components should be stored at 4°C upon arrival. Product is stable for 3 to 6 months after receipt. If Antibody Stripping Solution crystallizes upon storage, it may be re-dissolved with gentle warming at 37°C before use.

      Note: To prevent reagent degradation secure the cap tightly upon storage. Avoid extended exposure to air.
      Packaging Information
      Material Size1 kit
      Global Trade Item Number
      Catalogue Number GTIN
      2500 04053252515460