Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

Sample Preparation

MultiScreen plates offer diverse and versatile formats for a variety of preparative methods.

Overview

Specifications

Ordering Information

Go
MultiScreenHTS Filter Plates with Hydrophilic Durapore PVDF MembraneClear Sorting & Filtering Show Filter
Catalogue NumberPore SizeColor CodeDevice MaterialSterilityPack Size
MSGVN22100.22 µm Clear Styrene Non-Sterile 10
MSGVN22500.22 µm Clear Acrylic Non-Sterile 50
MSGVS22100.22 µm Clear Styrene Sterile 10
MSGVN2B500.22 µm Opaque Barex®/TiO<sub>2</sub> Non-Sterile 50
MSHVN45100.45 µm Clear Styrene Non-Sterile 10
MSHVN45500.45 µm Clear Styrene Non-Sterile 50
MSHVN4B500.45 µm Opaque Barex®/TiO<sub>2</sub> Non-Sterile 50
MSHVS45100.45 µm Clear Styrene Sterile 10
MSDVN65100.65 µm Clear Styrene Non-Sterile 10
MSDVN65500.65 µm Clear Styrene Non-Sterile 50
MSDVN6B500.65 µm Opaque Barex®/TiO<sub>2</sub> Non-Sterile 50
MSBVN12101.2 µm Clear Styrene Non-Sterile 10
MSBVN12501.2 µm Clear Styrene Non-Sterile 50
MSBVS12101.2 µm Clear Styrene Sterile 10
MSBVN1B501.2 µm Opaque Barex®/TiO<sub>2</sub> Non-Sterile 50
MVHVN45250.45 µm Opaque Polypropylene Non-Sterile 25

Back To Top

MultiScreenHTS Filter Plates with Hydrophilic MCE MembraneClear Sorting & Filtering Show Filter
Catalogue NumberPore SizeColor CodeDevice MaterialSterilityPack Size
MSHAN45100.45 µm Clear Styrene Non-Sterile 10
MSHAN45500.45 µm Clear Styrene Non-Sterile 50
MSHAS45100.45 µm Clear Styrene Sterile 10
MSHAN4B500.45 µm Opaque Barex®/TiO<sub>2</sub> Non-Sterile 50
MSHAS4B100.45 µm Opaque Barex®/TiO<sub>2</sub> Sterile 10

Back To Top

96-well MultiScreenHTS Filter Plates with Glass Fiber FilterClear Sorting & Filtering Show Filter
Catalogue NumberPore SizeColor CodeDevice MaterialSterilityPack Size
MSFBN6B101.0 / 0.65 µm Opaque Barex®/TiO<sub>2</sub> Non-Sterile 10
MSFBN6B501.0 / 0.65 µm Opaque Barex®/TiO<sub>2</sub> Non-Sterile 50
MSFCN6B101.2 / 0.65 µm Opaque Barex®/TiO<sub>2</sub> Non-Sterile 10
MSFCN6B501.2 / 0.65 µm Opaque Barex®/TiO<sub>2</sub> Non-Sterile 50
MVFCN12251.2 µm Opaque Polypropylene Non-Sterile 25

Back To Top

384-well MultiScreenHTS Filter Plates with Glass Fiber FilterClear Sorting & Filtering Show Filter
Catalogue NumberPore SizeColor CodeDevice MaterialSterilityPack Size
MZFBN0W101.0 / 0.65 µm Opaque Barex®/TiO<sub>2</sub> Non-Sterile 10
MZFBN0W501.0 / 0.65 µm Opaque Barex®/TiO<sub>2</sub> Non-Sterile 50
MZFCN0W101.2 / 0.65 µm Opaque Barex®/TiO<sub>2</sub> Non-Sterile 10
MZFCN0W501.2 / 0.65 µm Opaque Barex®/TiO<sub>2</sub> Non-Sterile 50

Back To Top

MultiScreen Solvinert Filter Plates with Hydrophilic PTFE MembraneClear Sorting & Filtering Show Filter
Catalogue NumberDescriptionPore SizePack Size
MSRLN0410MultiScreen Solvinert 96 Well Filter Plate 0.45 µm 10
MSRLN0450MultiScreen Solvinert 96 Well Filter Plate 0.45 µm 50
MDRLN0410MultiScreen Deep, 96 Well Solvinert 0.45 µm 10

Back To Top

MultiScreen Solvinert Filter Plates with Hydrophobic PTFE MembraneClear Sorting & Filtering Show Filter
Catalogue NumberDescriptionPore SizePack Size
MSRPN0410MultiScreen Solvinert 96 Well Filter Plate 0.45 µm 10
MSRPN0450MultiScreen Solvinert 96 Well Filter Plate 0.45 µm 50
MDRPN0410MultiScreen Deep, 96 Well Solvinert 0.45 µm 10

Back To Top

AccessoriesClear Sorting & Filtering Show Filter
Catalogue NumberDescriptionPack Size
WP6110060Chemical Duty Pump, 100 V/50–60 Hz 1
WP6111560Chemical Duty Pump, 115 V/60 Hz 1
WP6122050Chemical Duty Pump, 220 V/50 Hz 1
MSCPNPS0096-well Collection Plate 100
MSCPNPP0096-well Collection Plate 100
MDCPN2M5096 well Collection Plate 50
MACL09600MultiScreen Column Loader 1
MACL09680MultiScreen Column Loader 1
MACL09645MultiScreen Column Loader 1
MACL09625MultiScreen Column Loader 1
MSVMHTSHVMultiScreen High Volume Collar, 1 pk 1

Column Loaders are used to load chromatography media for column separations.

Back To Top

Documentation

References

Reference overviewApplication
Optimization of a simple, automatable extraction method to recover sufficient DNA from low copy number DNA samples for generation of short tandem repeat profiles.
Schiffner LA, Bajda EJ, Prinz M, Sebestyen J, Shaler R, Caragine TA.
Croat Med J. 2005 Aug;46(4):578-86.  2005

A platform for high-throughput molecular characterization of recombinant monoclonal antibodies
Mark J. Bailey, Andrew D. Hooker, Carolyn S. Adams, Shuhong Zhang, David C. James
J. of Chromatography B, 826 (2005) 177-187, 2005  2005

Antibody Purification

FAQ

QuestionAnswer
The Tech Note "TN053" entitled "Dye Terminator Removal and Sequencing Reaction Clean-up Using Multiscreen 96- Well Filtration Plates" states to add the sequencing reaction to the center of each well (already containing the prepared G-50 resin column). Can I add less than the standard 20ul volumes of sample to each column?Yes. You can add less. When adding volumes less than 10ul you should prewet the resin.
What type of scintillant do you recommend for use in MultiScreen?Although we don't recommend a specific type there are some guidelines. If the reading is done in the MultiScreen plate it important to use a scintilation fluid specific for microtiter plates. The standard scintillation fluid for reading in vials in higher volume and is mixed differently so it shouldn't be used with a microtiter plate.

MicroScint O is for organic and so it would be used with Durapore membrane. In our R&D labs, we have used MicroScint 20 and 40 interchangeably. Supermix (by Wallac) is a microtiter scintillant and has also been used interchangeably with MicroScint 20 and 40.
When I incubate MultiScreen plates, liquid leaks from the bottom of the plate. Is there a way to prevent leakage from the plate?Normally, the Multiscreen filtration plates do not leak when placed on a dry, non absorbent surface during incubation. If you are experiencing leakage, however, be certain that you have asked yourself the following questions:

1. Do I have a high surfactant concentration in the sample?
It is important that you not exceed .1% surfactant in each well.

2. Do I have organic solvents in my solution?
Although the Multiscreen plates have a limited tolerance to organic solevents it is important that you have verified that the concentration and type of solvent used in your assay is compatible with both the membrane and plate plastic. Otherwise, a solvent resistant plate may be more appropriate.

3. Is the underdrain coming in contact with an absorbent surface?
If you lay the plate on lab "chucks" it will cause liquid to wick out from the plate.

4. Have I inspected the plate bottom for microdroplets?
Be sure to blot the plate onto absorbent material prior to all incubations.
What is the well depth and maximum volume capacity of a MultiScreen plate?The well depth of a 96 well MultiScreen plate is 1.245 cm. The well depth for a 384 well MultiScreen plate is 1.2 cm. The maximum working volume of a 96 well plate is 300 ul. The maximum working volume for a 384 well plate is 100 ul.
I am using the Multiscreen system and my samples won't flow through the plate. What's wrong?There are a number of reasons why samples might not flow through the MultiScreen system. Be sure that the vacuum line is clear and not clogged. Be certain that your samples do not have a high particulate load. If they do, you may wish to dilute your samples in filtered buffers. Also, if you are working with cells, make sure that you do not have more than 10^6 cells in each well. If you are over this amount, dilute the cell suspension ot try working with a more open membrane ( larger pore size). Be certain that you do not have the lid on the Multiscreen system. this should be removed prior to filtering in the vacuum manifold. Finally , be sure that if you are not using a whole plate that you have sealed the empty wells with plate sealing tape.

In addition, ensure that the MultiScreen plate is forming a secure seal with the top gasket of the MultiScreen manifold. This can be checked by trying to lift the plate off the manifold with the vacuum on. If the seal is not secure press the four corners of the plate with the vacuum on to seal the plate.
I am using the Multiscreen system and the Multiple Punch assembly for liquid scintillation counting and I am not getting any counts. What might be causing this?Low or inconsistent counts most commonly results from the lack of release of the "labeled" material from the membrane. This is especially an issue with tritium. Millipore has developed a procedure for the release of radioactive label from membrane by adding 0.5 ml of dilute (0.42%) sodium hypochlorite to the scintillation vial containing the "punched" membrane and agitating for thirty minutes prior to the addition of the scintillation cocktail. Please request Technical Brief TB038 for additional details on this procedure.
I can't get any flow through the MultiScreen NA (lysate clearing plate) when performing the plasmid prep protocol. What's wrong?Clogging of the plate is usually due to inappropriate culture medium resulting in overgrowth or lysis. Use 2x LB, not terrific broth or another excessively rich medium.

Related Products & Applications

Product Families

Related Products By: Application Facete

Related Products By: Brand Facete

Categories

Life Science Research > Cell Culture and Systems > Cell Culture Flasks, Plates, & Slides > Multiwell Plates