Millipore Sigma Vibrant Logo

03-0201-00 SMC™ Human IgE High Sensitivity Immunoassay Kit

03-0201-00
96 well assay  
Retrieving price...
Price could not be retrieved
Minimum Quantity is a multiple of
Maximum Quantity is
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Fulfillment and delivery delayed
Fulfillment and delivery delayed
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Replacement Information

      Key Spec Table

      Analytes AvailableSpecies ReactivityKey Applications
      IgE HSingle Molecule Counting (SMC®)
      Description
      Catalogue Number03-0201-00
      Trade Name
      • SMC®
      DescriptionSMC™ Human IgE High Sensitivity Immunoassay Kit
      OverviewThe SMC™ Human IgE High Sensitivity Immunoassay Kit contains all reagents required to perform the assays. This assay takes advantage of a standard immunoassay workflow configured in a standard plate format. Assay protocols are similar to existing sandwich ELISA methods with two key differences: 1) Elution buffer disrupts the sandwich, separating the labeled detection antibody for quantification. 2) The SMC™ immunoassay system detects analytes using Single Molecule Counting (SMC™) technology.
      Background InformationThe Single Molecule Counting (SMC™) Human IgE High Sensitivity Immunoassay uses a quantitative fluorescent sandwich immunoassay technique to measure IgE in human serum and plasma samples. The user coats a capture antibody specific for human IgE onto a 96-well microplate. After blocking the plate, the user pipettes standards and samples into the coated microplate wells. During incubation, the IgE present in the sample binds to the capture antibody on the coated plate. Unbound molecules are washed away during a wash step. The fluor-labeled detection antibody is added to each well and incubated. The detection antibody recognizes and binds to IgE that has been captured onto the plate, thus completing the immunosandwich. Following the final wash step, elution buffer is added and incubated. The elution buffer dissociates the bound protein sandwich from the plate surface, releasing the labeled antibodies. These antibodies are separated during transfer to a final microplate. The reading plate is loaded onto the Erenna® or SMCxPRO™ System where the labeled molecules are detected and counted. The number of fluor-labeled detection antibodies counted is directly proportional to the amount of IgE present in the sample when captured. The amount of IgE in unknown samples is interpolated from a standard curve.
      References
      Product Information
      Components
      • Assay Plate
      • Coating Buffer
      • Blocking Buffer
      • Standard Diluent
      • IgM Detection Antibody
      • IgM Standard
      • SMC™ Human IgM Immunoassay Kit Instructions
      • 10X Wash Buffer
      • Buffer C
      • Elution Buffer B
      • Buffer 3
      • IgM Coating Antibody
      Precision, %
      • Intra-assay CV%: 7%
      • Inter-assay CV%: 12%
      Quality LevelMQ200
      Applications
      ApplicationThe Single Molecule Counting (SMC™) technology gives the SMC™ Human IgE High Sensitivity Immunoassay Kit offers researchers the ability to successfully overcome sample matrix challenges when accurately quantifying human IgM in serum and plasma samples
      Key Applications
      • Single Molecule Counting (SMC®)
      Biological Information
      SpecificityThis assay does not show cross-reactivity against immunoglobulin subclasses IgA, IgD, IdE, IgG1, IgG2, IgG3, or IgG4 from in-house testing
      IsotypeIgE
      Species Reactivity
      • Human
      Analytes Available
      • IgE
      Accuracy
      • Minimum of 5 samples spiked with acceptable recovery between 86-89%.
      Physicochemical Information
      Linearity of DilutionMinimum of 5 samples spiked and diluted (at least 3 dilutions) with acceptable recovery between 86-89%
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Usage Statement
      • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
      Storage and Shipping Information
      Packaging Information
      Material Size96 well assay
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      Catalogue Number GTIN
      03-0201-00 04065267540801

      Related Products & Applications

      Related Products

      Catalogue Number Description  
      03-0134-00 SMC™ Mouse IL-10 Discovery Immunoassay Kit Show Pricing & Availability
      03-0125-01 SMC™ Mouse IL-17F Discovery Immunoassay Kit Show Pricing & Availability

      Categories

      Life Science Research > Protein Detection and Quantification > Immunoassays > Enzyme-linked Immunosorbent Assay (ELISA) > Complete ELISA Kits