Millipore Sigma Vibrant Logo

PTSP24H48 Millicell Hanging Cell Culture Insert, PET 3 µm, 24-well, 48/pk

View Products on Sigmaaldrich.com
PTSP24H48
48  Individually blister packaged
Retrieving price...
Price could not be retrieved
Minimum Quantity is a multiple of
Maximum Quantity is
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Fulfillment and delivery delayed
Fulfillment and delivery delayed
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Replacement Information
      Description
      Catalogue NumberPTSP24H48
      Trade Name
      • Millicell
      DescriptionMillicell Hanging Cell Culture Insert, PET 3 µm, 24-well, 48/pk
      Background InformationWith Millicell inserts, attachment or suspension cells can access media from both their apical and basolateral sides. Cell growth, structure, and function more closely mimic what occurs in vivo. In addition, Millicell inserts make it possible to study both sides of the cell monolayer.

      Millicell inserts are available for 24-, 12-, or 6-well plates. The inserts are easily prepared for SEM and TEM visualizing techniques, and they are compatible with cellular and/or fluorescent stains.

      Insert Formats:
      Millicell Hanging Inserts:
      - For co-culturing and permeability assays
      - Unique design allows easier basolateral access than other hanging inserts with less risk of contamination
      - Available in 5 pore sizes and 3 diameters, including a 1 µm pore size that is optically transparent for better visualization by microscopy
      - NEW: Available preloaded in 24-well receiver plates or as individual inserts in 3 diameters


      Millicell Standing Inserts:
      - Promotes excellent cell growth and provides an exceptional opportunity for cell studies
      - Available with Biopore (PTFE) membrane, MF-Millipore (mixed cellulose esters) membrane, and polycarbonate membrane

      Millicell Organotypic Insert:
      - For high cell viability and superior study of three dimensional explant structure
      - Lower height allows them to fit inside a standard petri dish
      - The Biopore™ (PTFE) membrane provides high viability—for as long as 40 days—and excellent trans-membrane oxygen transport
      - The membrane is optically clear and optimized for long-term organotypic explant maintenance

      Membrane Types:
      Biopore Membrane (hydrophilic PTFE)
      - For low protein-binding, live cell viewing, and immunofluorescent applications

      MF-Millipore™ Membrane (mixed cellulose esters)
      - For exceptional anatomical and functional polarization

      Isopore™ Membrane (polycarbonate)
      - For growth of attachment-dependent cells without matrix

      PET Membrane (polyethylene terephthalate)
      - For growth of attachment-dependent cells without matrix

      With Millicell® inserts, adherent or suspension cells can access media from both their apical and basolateral sides. Cell growth, structure, and function more closely mimic what occurs in vivo. In addition, Millicell® inserts make it possible to study both sides of the cell monolayer.

      Applications

      Cell Attachment, Cell Growth, Cell Differentiation , Immunocytochemistry
      References
      Product Information
      Device Configuration24-well plate
      Filter CodePET
      Maximum Operating Temperature50 °C
      Number of Wells24
      Quality LevelMQ200
      Applications
      ApplicationPolyethylene Terephthalate hanging cell culture insert with pore size of 3.0 µm used in a 24-well plate for cell attachment, cell culture, cell differentiation & ICC.
      Key Applications
      • Cell Attachment
      • Cell Culture
      • Cell Differentiation
      • Immunocytochemistry
      Biological Information
      SterilitySterile
      Stem Cell Type
      • Mouse Embryonic Stem Cells
      • Human Embryonic Stem Cells
      • Mesenchymal Stem Cells
      • Neural Stem Cells
      • Hematopoietic Stem Cells
      • Epithelial Cells
      • Pancreatic Stem Cells
      • Cardiac Stem Cells
      • Induced Pluripotent Stem Cells
      Physicochemical Information
      Pore Size3.0 µm
      Recommended Media VolumeSee user guide
      Dimensions
      Filtration Area0.3 cm²
      Filter Diameter (⌀)6.5 mm
      Materials Information
      Chemistry
      • Polyethylene Terephthalate (PET)
      Device Material
      • Polystyrene
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size48
      Material PackageIndividually blister packaged
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      Catalogue Number GTIN
      PTSP24H48 04065268469064

      Related Products & Applications

      Product Families