Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

114552 Chromate Cell Test

Overview

Replacement Information

Products

Catalogue NumberPackaging Qty/Pack
1145520001 EPS box 25 tests
Description
Catalogue Number114552
OverviewThe method is analogous to APHA 3500-Cr B and DIN 38405-24.
USEPA approved for wastewater.

This Spectroquant® Chromate Cell Test allows the accurate quantification of the chromium(VI) and total chromium concentration in aqueous samples.

Method applied: In weakly phosphoric solution chromium(VI) ions react with diphenylcarbazide to form chromium(III) and diphenylcarbazone which form a red-violet complex that is determined photometrically.

The Spectroquant® Cell Tests come with prefilled 16 mm round cells and all the required reagents to perform the analysis according to the instruction leaflet provided.

All Spectroquant®Cell and Reagent Tests are equipped with the unique Live ID which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
References
Product Information
HS Code3822 19 90
Quality LevelMQ100
Applications
Biological Information
Physicochemical Information
Dimensions
Materials Information
Toxicological Information
Safety Information according to GHS
Hazard Pictogram(s) Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Statement(s)H272: May intensify fire; oxidizer.
H290: May be corrosive to metals.
H314: Causes severe skin burns and eye damage.
H317: May cause an allergic skin reaction.
H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
H335: May cause respiratory irritation.
Precautionary Statement(s)P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P220: Keep away from clothing and other combustible materials.
P280: Wear protective gloves/ protective clothing/ eye protection/ face protection/ hearing protection.
P303 + P361 + P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
P304 + P340 + P310: IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Signal WordDanger
Storage class5.1B Oxidizing hazardous materials
Safety Information
Product Usage Statements
Storage and Shipping Information
StorageStore at +15°C to +25°C.
Packaging Information
Transport Information
Declaration (railroad and road) ADR, RIDUN 3316 Chemie-Testsatz, 9, II
Declaration (transport by air) IATA-DGRUN 3316 CHEMICAL KIT, 9, II
Declaration (transport by sea) IMDG-CodeUN 3316 CHEMICAL KIT, 9, II
Supplemental Information
Specifications
Global Trade Item Number
Catalogue Number GTIN
1145520001 04022536155722

Documentation

Chromate Cell Test SDS

Title

Safety Data Sheet (SDS) 

Chromate Cell Test Certificates of Analysis

Product Number PackagingSpecificationLot Number
1145520001 EPS boxPDF Specification Document

Certificates

Title
114552 - Certificate of Quality - Spectroquant Chromate Cell Test / Chromat-Küvettentest / Test en cubetas Cromatos

Technical Info

Title
Chromate Spectroquant 114552_Comparison table 1999
Chromate Spectroquant 114552_Method 1999
Chromate Spectroquant WW Letter USEPA 1999
Programming data for Spectrophotometer and Spectroquant Test Kits
USEPA-approved Spectroquant®methods

User Guides

Title
Analytical Procedures and Appendices Spectroquant Prove 300
Analytical Procedures and Appendices Spectroquant®Prove 600
Manual Spectroquant Multy - Operating manual
Manual Spectroquant NOVA 30
Manual Spectroquant®Prove Connect to Dashboard - English
Manual Spectroquant®Prove Connect to LIMS - English
Quick Guide Spectroquant Photometer NOVA 60A (EN, DE, FR, ES, IT)
User Guide (IFU)-1.14552

Related Products & Applications

Alternative Products

Catalogue Number Description
114758 Chromate Test

Related Products

Catalogue Number Description
114758 Chromate Test

Accessories (Primary)

Catalogue Number Description
109137 Sodium hydroxide solution
109072 Sulfuric acid
114724 Empty cells 16 mm
119780 Chromate standard solution

Related Products By: Application Facete

Related Products By: Brand Facete

Categories

Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Boiler Water / Cooling Water > Chromate
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Milk
Analytics and Sample Preparation > Test Kits and Photometric Methods > Instrumental Test Systems for Quantitative Analyses > Photometric Measurements, Spectroquant® System > USEPA
Analytics and Sample Preparation > Test Kits and Photometric Methods > Instrumental Test Systems for Quantitative Analyses > Photometric Measurements, Spectroquant® System > Spectroquant® Tests
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Electroplating > Chromate
Analytics and Sample Preparation > Test Kits and Photometric Methods > Base Parameters from A to Z > Chromate
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Sea Water > Chromate
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Disposal Drainage Water > Chromate
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Construction Material > Chromate
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Environment > Chromate
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Waste Water > Chromate