Millipore Sigma Vibrant Logo
Atención: Nos hemos mudado. Los productos Merck Millipore ya no pueden adquirirse en MerckMillipore.comMás información

KHGES003HH3 Opticap® Sterile XL 300 Millipore Express® SHC 0.5/0.2 µm 9/16 in. HB/HB

KHGES003HH3
3  Double Easy-Open bag
Purchase on Sigma-Aldrich

Descripción

Replacement Information
Description
Catalogue NumberKHGES003HH3
Trade Name
  • Millipore Express®
DescriptionOpticap® Sterile XL 300 Millipore Express® SHC 0.5/0.2 µm 9/16 in. HB/HB
References
Product Information
HS Code8421 99 99
Device ConfigurationCapsule
Connections, Inlet/Outlet14 mm (9/16 in.) Hose Barb
Connections, Vent/Drain1/4 in. Hose Barb with double O-ring seal
Housing MaterialPolypropylene (PP)
Maximum Differential Pressure, bar (psid)Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
Maximum Inlet Pressure, bar (psi)6.9 bar (100 psi) intermittent @ 23 °C; 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Quality LevelMQ400
Applications
Biological Information
Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
MediaMillipore Express® SHC
SterilitySterile
Sterilization3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
WettabilityHydrophilic
Physicochemical Information
Pore Size0.5 / 0.2 µm
Inlet ConnectionHose Barb
Outlet ConnectionHose Barb
Air Diffusion at 23 °C≤1.9 mL/min @ 2.8 bar (40 psig) in water
Bubble Point at 23 °C≥4000 mbar (58 psig) air with water
Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
Maximum Inlet Pressure (psig)80 psig
Maximum Differential Pressure80 psi (5.5 bar) continuous
100 psi (6.9 bar) intermittent
Maximum Inlet Temperature25 °C
Non-Fiber ReleasingThis product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
TOC/ConductivityAfter sterilization and a controlled water flush of 2.0 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Dimensions
Cartridge Nominal Length4.7 in. (11.9 cm)
Length11.9 cm (4.7 in.)
Diameter5.6 cm (2.2 in.)
Filtration Area290 cm²
Inlet to Outlet Width11.9 cm (4.7 in.)
Inlet Connection Diameter9/16 in.
Outlet Connection Diameter9/16 in.
Materials Information
Chemistry
  • Polyethersulfone (PES)
Device Material
  • Gamma stable polypropylene/Polysulfone
Seal MaterialSilicone (SI)
Support MaterialPolyethylene
Vent Cap MaterialGamma stable polypropylene (PP)
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size3
Material PackageDouble Easy-Open bag
Transport Information
Supplemental Information
Specifications
Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
Global Trade Item Number
Número de referencia GTIN
KHGES003HH3 04053252300110

Documentation

Material Qualification Dossier

CargoVersión
1.0

Quality Management Dossier (Open Access)

Title

Operational Excellence Dossier

Title

Certificados de calidad

Cargo
Opticap L 300 Capsule Millipore Express SHC Membrane C8BA19217
Opticap XL 3 Capsule Millipore Express SHC Membrane C6SA40508
Opticap XL 300 Caosule Millipore Express SHC Membrane C7CA94302
Opticap XL 300 Capsule Millipore Express SHC Membrane C0SB24225
Opticap XL 300 Capsule Millipore Express SHC Membrane C0AB88273
Opticap XL 300 Capsule Millipore Express SHC Membrane C0DB58527
Opticap XL 300 Capsule Millipore Express SHC Membrane C0MB92040
Opticap XL 300 Capsule Millipore Express SHC Membrane C1EB95414
Opticap XL 300 Capsule Millipore Express SHC Membrane C2PB18032
Opticap XL 300 Capsule Millipore Express SHC Membrane C2SB54519

Licencias necesarias e Información técnica

Cargo
Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters
Extended bacterial retention testing of Millipore Express® 0.2 μm filters in a continuous flow system
Simplified, efficient sizing of sterilizing-grade normal flow filters for buffer solutions

Ficha técnica

Cargo
Millipore Express®SHC Hydrophilic Filters

Manuales del usuario

Cargo
Opticap® XL Capsules and Opticap® XLT Capsules
User Guide - Filters with Millipore Express®Membrane
Vmax Constant Pressure

Productos y aplicaciones relacionados

Familias de productos

Productos relacionados por: Brand Facete

Categorías

Biopharmaceutical Manufacturing > Downstream Processing > Sterile Filtration > Sterile Liquid > Millipore Express® > Millipore Express® SHC