Millipore Sigma Vibrant Logo
Atención: Nos hemos mudado. Los productos Merck Millipore ya no pueden adquirirse en MerckMillipore.comMás información

E461-90020 NovaSeptum® GO, AV Application, 20 ml

E461-90020
40  
Purchase on Sigma-Aldrich

Descripción

Replacement Information
Description
Catalogue NumberE461-90020
Trade Name
  • NovaSeptum®
DescriptionNovaSeptum® GO, AV Application, 20 ml
References
Product Information
HS Code3926 90 90
Device ConfigurationSingle sampling
Fitting InletSeptum unit with a 2 mm needle
Fitting OutletFemale or Male Luer in PVDF
Maximum Sampling Pressure0.5 bar (7.25 psi)
Maximum Operating TemperatureSingle 20mL: -80 to 121 °C (-112 to 250 °F)
Quality LevelMQ400
Applications
ApplicationSterility testing, pyrogenic testing, endotoxin testing, chemical analysis, pH analysis, and fermentation applications
Biological Information
Bacterial EndotoxinsAqueous extraction contains ≤2.15 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
SterilitySterile
SterilizationBeta Irradiation (e-beam) minimum 25 kGy according to ISO 11137 TIR No. 27
Physicochemical Information
Dimensions
Needle Size2.0 mm
Volume20 mL
Materials Information
Device Material
  • Syringe: polycarbonate, medical grade, platinum-cured silicone, medical silicone fluid
Tubing MaterialMedical grade, platinum-cured silicone
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size40
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Número de referencia GTIN
E461-90020 04061841097853

Documentation

Certificados de calidad

Cargo
NOVASEPTUM® GO Accurate Volume Application - 190801-504
NovaSeptum® GO - 220519-503
NovaSeptum® GO - 220705-508
NovaSeptum® GO - 220803-502
NovaSeptum® GO - 220829-504
NovaSeptum® GO - 240606-505
NovaSeptum® GO Accurate Volume Application - 200911-502
NovaSeptum® GO Accurate Volume Application - 201008-501
NovaSeptum® GO Accurate Volume Application - 201029-502
NovaSeptum® GO Accurate Volume Application - 210113-504

Licencias necesarias e Información técnica

Cargo
NovaSeptum®GO Bottle Sampling Unit Specification Sheet
NovaSeptum®GO Pre-loaded Disposable Magazine Specification Sheet
NovaSeptum®GO Vented Autoclave Sampling Unit Specification Sheet

Ficha técnica

Cargo
Data Sheet: NovaSeptum® GO Sterile Sampling System

Manuales del usuario

Cargo
NovaSeptum® and NovaSeptum® GO Sampling Units