Millipore Sigma Vibrant Logo
Atención: Nos hemos mudado. Los productos Merck Millipore ya no pueden adquirirse en MerckMillipore.comMás información

MFHL10ST3 Gamma sterilized Millipak® Final Fill 100 Filter Unit 0.45  µm 1 1/2  in. TC/TC

MFHL10ST3
3  Double Easy-Open bag
Purchase on Sigma-Aldrich

Descripción

Replacement Information
Description
Catalogue NumberMFHL10ST3
Trade Name
  • Millipak®
DescriptionGamma sterilized Millipak® Final Fill 100 Filter Unit 0.45  µm 1 1/2  in. TC/TC
References
Product Information
Device ConfigurationGamma Gold Capsule
Connections, Inlet/Outlet38  mm (1½  in.) sanitary flange inlet and outlet
Maximum Differential Pressure, bar (psid)Foward:80 psi (5.5 bar) at 25 °C (0.1 µm, 0.22 µm, 0.45 µm, hydrophobic 0.22 µm); Reverse: 10 psi (0.7 bar) at 25 °C
Maximum Inlet Pressure, bar (psi)80 psi (5.5 bar) at 25 °C
Good Manufacturing PracticesThese products are manufactured in a facility which is certified to ISO® 9001:2015 Quality Management Systems.
Quality LevelMQ400
Applications
Biological Information
Bacterial EndotoxinsAqueous extraction contains < 0.25 EU/mL per device as determined using the Limulus Amebocyte Lysate (LAL) test, meeting requirements of USP <85>, EP 2.6.14 and JP 4.01.
MediaDurapore®
Sterilitysterilized by gamma irradiation
SterilizationDevice integrity and retention was maintained after 3 autoclave cycles of 90 minutes at 126  °C. Devices can withstand a dose ≤ 40  kGy gamma exposure.
WettabilityHydrophilic
Physicochemical Information
Pore Size0.45 µm
Inlet ConnectionSanitary Flange
Outlet ConnectionSanitary Flange
Bubble Point at 23 °C≥ 26 psi (1790 mbar) air with water
Flow Rate3.0 L/min @ 0.69   bar ∆P
Non-Fiber ReleasingThis product was manufactured with a Durapore® membrane which meets the criteria for a “non-fiber releasing” filter as defined in 21 CFR 210.3 (b)(6), validated based on large volume parenteral specifications as detailed in USP <788> Particulate Matter in Injections
USP Bacterial EndotoxinsAqueous extraction contains < 0.25 EU/mL per device as determined using the Limulus Amebocyte Lysate (LAL) test, meeting requirements of USP <85>, EP 2.6.14 and JP 4.01.
Dimensions
Filtration Area500 cm²
Process Volume100 L
Inlet Connection Diameter1 1/2 in.
Outlet Connection Diameter1 1/2 in.
Materials Information
Chemistry
  • Polyvinylidene Fluoride (PVDF)
Device Material
  • Polysulfone
Support MaterialPolysulfone
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size3
Material PackageDouble Easy-Open bag
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Número de referencia GTIN
MFHL10ST3 04054839379222

Documentation

Material Qualification Dossier

CargoVersión
1.0

Operational Excellence Dossier

Title

Certificados de calidad

Cargo
Millipak Final Fill Capsule Durapore Membrane C2HB90015
Millipak Final Fill Capsule Durapore Membrane C2MB10976
Millipak Final Fill Capsule Durapore Membrane C2PB36723

Licencias necesarias e Información técnica

Cargo
Improved Product Recovery using Blow-down and Millipak®Final Fill Filters
Integrity Test Troubleshooting - Beyond Rewet and Retest
Reduce Contamination Risks and Simplify Filtration System Design and Operation

Manuales del usuario

Cargo
Wetting Instructions for Filter Units with Durapore Membrane

Productos y aplicaciones relacionados

Familias de productos