KEGBG050HH00 Gamma Phobic Opticap® XL 50 Express SPG 0.2 HB/HB

KEGBG050HH00
100  
Purchase on Sigma-Aldrich

Descripción

Replacement Information
Description
Catalogue NumberKEGBG050HH00
Trade Name
  • Opticap®
DescriptionGamma Phobic Opticap® XL 50 Express SPG 0.2 HB/HB
References
Product Information
Device ConfigurationCapsule
Connections, Inlet/OutletStepped Hosebarb Inlet and Outlet for silicone flexible tubing with 6.5 to 9.5 mm internal diameter; female Luer slip interior
Maximum Differential Pressure, bar (psid)Forward: 4.2 bar (60 psid) @ 25 °C; Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
Maximum Inlet Pressure, bar (psi)4.1 bar (60 psi) @ 23 °C
Quality LevelMQ400
Applications
Key Applications
  • Small scale single-use applications
Biological Information
Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
MediaMillipore Express® SPG
SterilityNon-Sterile
SterilizationGamma compatible to 45 kGy; OR 3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Bacterial RetentionQuantitative retention of 107 CFU/cm2 Brevundimonas diminuta (ATCC® 19146) per ASTM® methodology
WettabilityHydrophobic
Physicochemical Information
Pore Size0.2 µm
Outlet ConnectionHose Barb
Bubble Point at 23 °C≥1170 mbar (17 psig) air with 100% IPA solution
Gravimetric Extractables≤1.0 mg in 70/30 % IPA/water
HydroCorr≤0.03 mL/min @ 2.6 bar (38 psig)
Dimensions
Length7.2 cm (2.84 in.)
Diameter6.2 cm (2.4 in.)
Filtration Area19.6 cm²
Materials Information
Chemistry
  • Hydrophobic Polyethersulfone (PES)
Device Material
  • Gamma-stable polybutylene terephthalate based blend
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size100
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Número de referencia GTIN
KEGBG050HH00 04053252634123

Documentation

Certificados de calidad

Cargo
GAMMA OPTICAP XL 50 - F5JA20675
GAMMA OPTICAP XL 50 - F5MA56753
GAMMA OPTICAP XL 50 - F5NA72691
GAMMA OPTICAP XL 50 - F5PA85589
GAMMA OPTICAP XL 50- F4MA04411
GAMMA OPTICAP XL 50- F4NA18887
Gamma Optical XL 50- F5AA46724
Gamma Opticap XL 50 CApsule Filter with Millipore Express SPG Hydrophobic Membrane - F4AA76209
Gamma Opticap® XL 50 Capsule Filter with Millipore Express® SPG Hydrophobic Membrane - F0BB83347
Gamma Opticap® XL 50 Capsule Filter with Millipore Express® SPG Hydrophobic Membrane - F0KB04314

Licencias necesarias e Información técnica

Cargo
Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters
Performance of Gamma Stable Opticap®XL 50 Capsule Filter with Millipore Express®SPG Membrane vs. Competitor’s 50 mm Gamma Stable Hydrophobic PVDF Membrane Filter for a Typical Fed Batch Cell Culture Process
Vent Filter Sizing for Mobius®Single-use Mixing Solution

Ficha técnica

Cargo
Gamma Stable Opticap®XL Capsule Filters with Millipore Express®SPG Hydrophobic Membrane

Manuales del usuario

Cargo
Wetting Instructions for Filter Units with Durapore Membrane