UFC901024 Amicon® Ultra-15 Centrifugal Filter Unit

UFC901024
24  
Purchase on Sigma-Aldrich

Overview

Replacement Information

Key Spec Table

Key ApplicationsNMWLVolumeMinimum Final Concentrate Volume
PExt, Protein Purification10 KDa15 mL200 µL
Description
Catalogue NumberUFC901024
Trade Name
  • Amicon Ultra
DescriptionAmicon® Ultra-15 Centrifugal Filter Unit
Background InformationAMICON ULTRA-15 15ML - 10 KDa cutoff. Available in 3 pack sizes.
UFC901008 - 8 pack
UFC901024 - 24 pack
UFC901096 - 96 pack



High recovery Ultracel regenerated cellulose membrane in a range of molecular weight cut-offs
High retentate recovery of greater than 90%
Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 10–15 minutes)
Heat-sealed membrane minimizes downstream extractables
100% integrity tested for reliable performance
Convenient sample monitoring with translucent housing and volume gradations
Direct pipettor sample access eliminates processing step to recover concentrate
High concentration factors of 80–100X

Applications:
Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms
Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLS
Concentration of dilute or pre-purified proteins from column eluents
Desalting, buffer exchange and protein dialysis
References
Product Information
HS Code8421 29 90
Filter CodePLGC
Color CodeClear with pink cap
Filter TypeUltrafiltration
NMWL10 KDa
Quality LevelMQ400
Applications
ApplicationUltracel-10 regenerated cellulose membrane, 15 mL sample volume
Key Applications
  • Protein Extraction
  • Protein Purification
Biological Information
SterilityNon-Sterile
Physicochemical Information
Centrifugal ApplicationProtein Concentration and Desalting
Dimensions
Length12.1 cm (4.807 in.)
Diameter2.97 cm
Filtration Area7.6 cm²
Minimum Final Concentrate Volume200 µL
Volume15 mL
Materials Information
Chemistry
  • Regenerated Cellulose (RC)
Device Material
  • Housing: Styrene/butadiene
  • Tube: Polypropylene
  • Cap and liner: Polyethylene
Support MaterialRegenerated cellulose
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size24
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
Catalogue Number GTIN
UFC901024 04054839076633

Documentation

References

Reference overviewPub Med ID
Large-Scale Filter-Aided Sample Preparation Method for the Analysis of the Ubiquitinome.
Casanovas A, Pinto-Llorente R, Carrascal M, Abian J
Anal Chem  89(7)  3840-3846  2017

Show Abstract
28260372 28260372
A complex of Protocadherin-19 and N-cadherin mediates a novel mechanism of cell adhesion.
Emond, Michelle R, et al.
J. Cell Biol., 195: 1115-21 (2011)  2011

Show Abstract
22184198 22184198

Certificates of Quality

Title
UFC901024 0000234282

Brochure

Title
REFINE PROTEIN PREPARATION. Tools for better protein analysis
Western Blotting Tools

Posters

Title
A centrifugal ultrafiltration-based method for enrichment of microvesicles

FAQ

QuestionAnswer
Amicon Ultra units are offered in what volumes?Amicon Ultra units are available in 0.5 mL, 4mL & 15ml volumes.
What is the recommended rotor for Amicon Ultra units?Any rotor capable of accommodating 22.7 cm in diameter and 124 mm length centrifuge tubes for the Amicon Ultra-4 and 35 mm in diameter and 121 mm in length for the Amicon Ultra-15 can be used for Amicon Ultra units.
How should I select the appropriate Molecular Weight Cutoff (MWCO) for Amicon Ultra?Select a Molecular Weight Cutoff that is 2x smaller that the Molecular Weight (MW) of the solute of interest.
Which membranes are available in Amicon Ultra units?Amicon Ultra units are only available with Ultracel regenerated cellulose material. This high recovery/low binding membrane is offered in 3,000, 10,000, 30,000, 50,000 & 100,000 MWCO.
Can the Amicon Ultra be spun to dryness?No, the Amicon Ultra has a built in deadstop.
Can the Amicon Ultra be used with nucleic acids?Yes, Amicon Ultra units have been evaluated for use with Genomic and PCR fragments. The 30 kDa MWCO provides the best balance between recovery and spin time. Protocols related to Genomic and PCR fragments can be found in the user guide.
What is the maximum sample volume for Amicon Ultra?
Amicon Ultra-4Amicon Ultra-15
Swinging Bucket4ml 15ml
Fixed Angle4ml(35 & 45 degree rotor angle)12ml(35 degree rotor angle)
3.5ml(23 degree rotor angle)
What is the maximum centrifugal force I can spin Amicon Ultra-4 & Amicon Ultra-15?
4ml15ml
Swinging Bucket4000 x g4000 x g
3500 x g for concentrated/viscous solutions
Fixed Angle(23, 35 &45 degrees)7500 x g5000 x g
What is the chemical compatibility of Amicon Ultra?Amicon Ultra units are intended for use with biological fluids and aqueous solutions. Please refer to the user guide, catalogue, or contact Technical Support.
Can Amicon Ultra units be sterilized with ethanol?Amicon Ultra is compatible with 70% Ethanol, but we have not done any studies to test for sterilization.