Millipore Sigma Vibrant Logo

KVVLG04TT3 Opticap® Gamma Compatible Sterilizing Grade XL4 Durapore® 0.1 µm 1-1/2 in. TC/TC

View Products on Sigmaaldrich.com
KVVLG04TT3
3  Double Easy-Open bag
Retrieving price...
Price could not be retrieved
Minimum Quantity is a multiple of
Maximum Quantity is
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Fulfillment and delivery delayed
Fulfillment and delivery delayed
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Replacement Information
      Description
      Catalogue NumberKVVLG04TT3
      Trade Name
      • Opticap®
      DescriptionOpticap® Gamma Compatible Sterilizing Grade XL4 Durapore® 0.1 µm 1-1/2 in. TC/TC
      References
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet38 mm (1-1/2 in.) Sanitary Flange
      Connections, Vent/Drain1/4 in. Hose Barb with double O-ring Seal
      Housing MaterialPolypropylene (PP)
      Maximum Differential Pressure, bar (psid)Forward: 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.8 bar (40 psid) @ 25 °C, intermittent
      Maximum Inlet Pressure, bar (psi)5.5 bar (80 psi) @ 23 °C; 2.8 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Quality LevelMQ400
      Applications
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.5 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaDurapore®
      SterilityNon-sterile, Gamma compatible
      Sterilization3 autoclave cycles of 60 min @ 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.1 µm
      Inlet ConnectionSanitary Flange
      Outlet ConnectionSanitary Flange
      Air Diffusion at 23 °C≤5.7 mL/min @ 3.9 bar (56 psig) in water
      Bubble Point at 23 °C≥4830 mbar (70 psig) air with water
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Inlet Pressure (psig)80 psig
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a Durapore® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      TOC/ConductivityAfter sterilization and a controlled water flush, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 ºC.
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length4 in. (10 cm)
      Length17.0 cm (6.7 in.)
      Diameter6.1 cm (2.4 in.)
      Filtration Area0.18 m²
      Device Size4 in.
      Inlet Connection Diameter1-1/2 in.
      Outlet Connection Diameter1-1/2 in.
      Materials Information
      Chemistry
      • Polyvinylidene Fluoride (PVDF)
      Device Material
      • Gamma-stable polypropylene
      Seal MaterialLead O-ring: Silicone-coated EPDM, Outer O-ring: Silicone
      Support MaterialPolyester
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size3
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥500 mL
      Global Trade Item Number
      Catalogue Number GTIN
      KVVLG04TT3 04053252377075

      Documentation

      Material Qualification Dossier

      TitleVersion
      2.0

      Operational Excellence Dossier

      Title

      Certificates of Quality

      Title
      Opticap XL 4 Capsule Durapore Membrane C1SB03091Z
      Opticap XL 4 Capsule Durapore Membrane C1DB90908Z
      Opticap XL 4 Capsule Durapore Membrane C4NB04716
      Opticap XL 4 Capsule Durapore Membrane C8NA13436
      Opticap XL 4 Capsule Durapore Membrane - C7CA84149
      Opticap XL 4 Capsule Durapore Membrane -C9SA22160
      Opticap XL 4 Capsule Durapore Membrane C1KB51495Z
      Opticap XL 4 Capsule Durapore Membrane C2CB41212Z
      Opticap XL 4 Capsule Durapore Membrane C4BB16027
      Opticap XL 4 Capsule Durapore Membrane C7EA16335

      Technical Info

      Title
      Establishing Product Specific Bubble Point Specifications For Sterilizing-Grade Filters
      Simplified, efficient sizing of sterilizing-grade normal flow filters for buffer solutions

      Data Sheet

      Title
      Durapore® Family Guide

      User Guides

      Title
      Opticap® XL Capsules and Opticap® XLT Capsules

      Related Products & Applications

      Product Families

      Related Products By: Brand Facete

      Categories

      Biopharmaceutical Manufacturing > Downstream Processing > Sterile Filtration > Sterile Liquid > Durapore