Millipore Sigma Vibrant Logo

103973 M-GLAS®

View Products on Sigmaaldrich.com
103973
View Pricing & Availability

Overview

Replacement Information

Pricing & Availability

Catalogue Number AvailabilityPackaging Qty/Pack Price Quantity
1039730001
Retrieving availability...
Fulfillment and delivery delayed
Fulfillment and delivery delayed
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

      Glass bottle 500 ml
      Retrieving price...
      Price could not be retrieved
      Minimum Quantity is a multiple of
      Maximum Quantity is
      Upon Order Completion More Information
      You Saved ()
       
      Request Pricing
      Description
      Catalogue Number103973
      DescriptionM-GLAS®
      OverviewM-GLAS® liquid cover glass for microscopy, is used in cytology instead of a cover glass to ensure that the stained specimens are homogenously covered. A few drops are applied onto the specimen, taking care that the mounting medium is evenly distributed over the specimen material. After the solvent has evaporated, a solid, protective lacquer film remains that ensures that the specimen material is preserved. The M-GLAS® layer is not resilient to immersion oils. In exceptional cases, the time for which the specimen is exposed to the immersion oil should be kept to less than 10 minutes, since otherwise a residue-free removal of the oil can no longer be guaranteed. If the exposure time is longer, it is recommended to remove as much of the immersion oil from the specimen as possible, immerse it in xylene, and to mount it anew.This product is registered as IVD and CE marked. For more details, please see instructions for use (IFU). The IFU can be downloaded from this webpage.

      Refractive index (20°C) 1.490 - 1.500
      Density (20°C / 4°C) 0.980 g/cm3
      Viscosity (20°C) 500 - 600 mPa*s
      Fluorescence < 250 ppb
      References
      Product Information
      HS Code3208 20 10
      Quality LevelMQ400
      Applications
      Applicationliquid cover glass for microscopy
      Biological Information
      Physicochemical Information
      Density0.91 g/cm3 (20 °C)
      Explosion limit1.2 - 8 %(V) toluene
      Flash point8 °C
      Ignition temperature>250 °C
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Hazard Pictogram(s) Hazard Pictogram(s)
      Hazard Pictogram(s)
      Hazard Pictogram(s)
      Hazard Statement(s)H225: Highly flammable liquid and vapour.
      H304: May be fatal if swallowed and enters airways.
      H315: Causes skin irritation.
      H336: May cause drowsiness or dizziness.
      H361d: Suspected of damaging the unborn child.
      H373: May cause damage to organs through prolonged or repeated exposure.
      H412: Harmful to aquatic life with long lasting effects.
      Precautionary Statement(s)P202: Do not handle until all safety precautions have been read and understood.
      P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
      P273: Avoid release to the environment.
      P301 + P310: IF SWALLOWED: Immediately call a POISON CENTER/doctor.
      P303 + P361 + P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
      P331: Do NOT induce vomiting.
      P403 + P233: Store in a well-ventilated place. Keep container tightly closed.
      Signal WordDanger
      Storage class3 Flammable liquids
      WGKWGK 3 highly hazardous to water
      Disposal3
      Relatively unreactive organic reagents should be collected in container A. If halogenated, they should be collected in container B. For solid residues use container C.
      Safety Information
      Categories of dangerhighly flammable, irritant, harmful, toxic for reproduction
      Product Usage Statements
      Storage and Shipping Information
      StorageStore at +15°C to +25°C.
      Packaging Information
      Transport Information
      Declaration (railroad and road) ADR, RIDUN 1866 , 3, II
      Declaration (transport by air) IATA-DGRUN 1866 , 3, II
      Declaration (transport by sea) IMDG-CodeUN 1866 , 3, II
      Supplemental Information
      Specifications
      Global Trade Item Number
      Catalogue Number GTIN
      1039730001 04022536045528

      Related Products & Applications

      Accessories (Primary)

      Catalogue Number Description  
      100869 Entellan™ new for cover slipper Show Pricing & Availability
      101691 Canada balsam Show Pricing & Availability
      107960 Entellan™ Show Pricing & Availability
      107961 Entellan™ new Show Pricing & Availability
      109016 Neo-Mount™ Show Pricing & Availability
      115355 CYTOCOLOR™ Cytological standard stain acc. to Szczepanik Show Pricing & Availability

      Accessories (Secondary)

      Catalogue Number Description  
      100869 Entellan™ new for cover slipper Show Pricing & Availability
      107960 Entellan™ Show Pricing & Availability

      Related Products By: Application Facete

      Related Products By: Brand Facete

      Categories

      IVD/OEM Materials & Reagents > Microscopy > Cytology > Auxiliaries for Cytology
      IVD/OEM Materials & Reagents > Microscopy > Universal Reagents > Mounting