Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

Pellicon® XL 50 Ultrafiltration Cassettes

True linear scalability with UF membranes with the same flow path and channel height as larger Pellicon® 2 cassettes. The Pellicon XL 50 allows process development and scaling studies.

概述

规格

订货信息

继续

Documentation

参考

参考概述
Scaling Up with Tangenital Flow Filtration
Campbell, Melissa; Coons, Elizabeth
GEN; v. 21, no. 16; Sept. 15, 2001, p. 60  2001

Linear Scale Ultrafiltration
van Reis, Robert, Elizabeth M. Goodrich, Christine L. Yson, Leah N. Frautschy, Stephen Dzengeleski, and Herb Lutz
Biotechnology & Bioengineering (September 1997): 737-746.  1997

Clean-Water Permeability as a Determinant of Cleaning Efficacy in Tangential-Flow Filtration Systems
Michaels, Stephen L.; RP016
RP016  1994

Validation of Tangential Flow Filtration (TFF) Systems
Michaels, Stephen L.
Journal of Parenteral Science and Technology (Sept/Oct 1991).  1991

问与答

问题回答
What is the sample volume range for the Pellicon II Mini system?The Pellicon II Mini system is capable of volumes in the approximate range of 1- 50 L concentrating down to 100 mL. More or less volume can be processed depending on the individual needs of the operation, ie. process time, sensitivity of product, etc.
What is the part number for the Gauge Kit that is used with the Pellicon XL?Gauge Kit for Pellicon XL Device (0-60 psi):
Part number XXPXLGAGE, 1 per kit. Includes an inlet pressure gauge and t-fitting. This gauge is recommended when the Pellicon is used in the absence of a Labscale TFF system in order to ensure that the pressure on the tubing is known and not allowed to exceed it's recommended maximum.
Can I use TFF systems to separate two proteins based on a significant difference in their respective molecular weights?As a general rule ultrafiltration does not provide high efficiency separations of protein mixtures. However, it may be possible to effect this type of separation between two proteins that have at least 10 X difference in molecular weight and if there is an ultrafiltration membrane available with a NMWL rating between the molecular weight of the two proteins. These separations are also generally more successful with dilute protein solutions and if run at low pressure.

相关产品和应用

产品族

相关产品,按下列排序: Application Facete

相关产品,按下列排序: Brand Facete

种类

Biopharmaceutical Manufacturing > Downstream Processing > Ultrafiltration