Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

使用珠子的分析

MultiScreenHTS filter plates have been specifically developed for compatibility with the solvents needed for combinatorial chemistry bead cleavage steps.

概述

规格

订货信息

继续
MultiScreenHTS 滤膜板,内置亲水性 Durapore PVDF 膜清除排序和过滤条件 Show Filter
产品目录编号描述装置材料孔径无菌性包装大小
MSHVN4510MultiScreenHTS HV,0.45 µm,无色,非无菌 苯乙烯 0.45 µm 非无菌 10
MSHVN4550MultiScreenHTS HV,0.45 µm,无色,非无菌 苯乙烯 0.45 µm 非无菌 50
MSHVS4510MultiScreenHTS HV,0.45 µm,无色,无菌 苯乙烯 0.45 µm 无菌 10
MSDVN6510MultiScreenHTS DV,0.65 µm,无色,非无菌 苯乙烯 0.65 µm 非无菌 10
MSDVN6550MultiScreenHTS DV,0.65 µm,无色,非无菌 苯乙烯 0.65 µm 非无菌 50
MSDVN6B50MultiScreenHTS DV,0.65 µm,不透明,非无菌 Barex/TiO<sub>2 </sub> 0.65 µm 非无菌 50
MSBVN1210MultiScreenHTS BV,1.2 µm,无色,非无菌 苯乙烯 1.2 µm 非无菌 10
MSBVN1250MultiScreenHTS BV,1.2 µm,无色,非无菌 苯乙烯 1.2 µm 非无菌 50
MSBVS1210MultiScreenHTS BV,1.2 µm,无色,无菌 苯乙烯 1.2 µm 无菌 10

返回顶部

MultiScreen 耐溶剂滤膜板,内置亲水性 PTFE 膜清除排序和过滤条件 Show Filter
产品目录编号描述装置材料孔径包装大小
MSRLN0410MultiScreen Solvinert,亲水性 PTFE,0.45 µm,无色,非无菌 聚烯烃共聚物 0.45 µm 10
MSRLN0450MultiScreen Solvinert,亲水性 PTFE,0.45 µm,无色,非无菌 聚烯烃共聚物 0.45 µm 50
MDRLN0410MultiScreen 深孔 Solvinert,亲水性 PTFE,0.45 µm,无色,非无菌 聚烯烃共聚物 0.45 µm 10

返回顶部

Accessories清除排序和过滤条件 Show Filter
产品目录编号描述包装大小
MSVMHTS00MultiScreenHTS 真空多联装置 1
MSVMHTS0D深孔环管 1
MACF09604MultiScreen 离心连接框,蓝色,用于水溶液 4
WP6111560Chemical Duty 泵,115 V/60 Hz 1
WP6122050Chemical Duty 泵,220 V/50 Hz 1
WP6110060Chemical Duty 泵,100 V/50–60 Hz 1
MATAHCL00MultiScreen 密封胶片,无色,非无菌 100
MACL09625MultiScreen 装柱器,25 µL,黑色,铝制,非无菌 1
MACL09645MultiScreen 装柱器,45 µL,黑色,铝制,非无菌 1
MACL09680MultiScreen 装柱器,80 µL,黑色,铝制,非无菌 1
MACL09600MultiScreen 装柱器,100 µL,黑色,铝制,非无菌 1
MACL0SC03用于 MultiScreen 装柱器 的刮器 3
MSCPNPS0096 孔收集板,无色,非无菌 100
MSCPNUV4096 孔 MultiScreenHTS 收集板,用于 UV 分析,非无菌 40
MSCPNPP0096 孔 V型底收集板 100

装柱器用于装量柱分离的层析培养基。

返回顶部

Documentation

参考

参考概述应用
Kinetics and isotype profile of antibody responses in rhesus macaques induced following vaccination with HPV 6, 11, 16 and 18 L1-virus-like particles formulated with or without Merck aluminum adjuvant
Wanda Ruiz, William McClements, Kathrin Jansen, and Mark esser
Journal of Immune Based Therapies and Vaccines 2005, 3:2  2005

Bead-based Assays
Use of ADME screening to conserve resources in drug discovery and development
Weiss, A. and Joseph Machamer
American Biotechnology Laboratory, January 2004: 16-17  2004

Screening for pharma gold: Researchers are using membrane technologies for high-throughput ADME analysis
Lynch, John,Modern Drug Discovery, January 2004: 27-28
Modern Drug Discovery, January 2004: 27-28  2004

Scintillation proximity assay of inositol phosphates in cell extracts: High-throughput measurement of G-protein-coupled receptor activation
Philip E. Brandish, Lorraine A. Hill, Wei Zheng and Edward M. Scolnick
Analytical Biochemistry 313 (2): 311-318  2003

Bead-based Assays
Functional roles of conserved transmembrane prolines in the human VPAC1 receptor.
Sanne Moller Knudsen, Jeppe Wegener Tams and Jan Fahrenkrug; Journal of Biochemical and Biophysical Methods 40 (3): 113-117
Journal of Biochemical and Biophysical Methods 40 (3): 113-117  2001

Bead-based Assays
A high-throughput assay for rat liver Golgi and Saccharomyces cerevisiae-expressed murine CMP-N-acetylneuraminic acid transport proteins
Tiralongo J; Abo S; Danylec B; Gerardy Schahn R; vonItzstein M
Analytical Biochemistry 2000 , v285, n1, p21-32  2000

Bead-based Assays
Designing new metal affinity peptides by random mutagenesis of a natural metal-binding site.
Markus M. Enzelberger, Stefan Minning and Rolf D. Schmid
Journal of Chromatography A 898 (1): 83-94  2000

Bead-based Assays
Quantification of telomerase activity by direct scintillation counting.
Sonja Kazmer, Keh-Ming Pan and Lyubomir Vassilev
Journal of Biochemical and Biophysical Methods 40 (3): 113-117  1999

Bead-based Assays
Microplate Chromatography Assay for Acety1-CoA: Lysoplatelet-Activating Factor Acetyltransferase1
Kume, K., Waga, I., Shimizu, T.
Analytical Biochemistry 246:, 118-122  1997

Bead-based Assays
Evaluation of Islet Cell Antigen (ICA)512/IA-2 Autoantibody Radioassays Using Overlapping ICA512/IA-2 Constructs
Kawaski, E., Yu, L., Gianani, R., Verge, C.F., Babu, S., Bonifacio, E., Eisenbarth, G.S.
Journal of Clinical Endocrinology & Metabolism 82:2, 375-380  1997

Bead-based Assays

问与答

问题回答
What is the well depth and maximum volume capacity of a MultiScreen plate?The well depth of a 96 well MultiScreen plate is 1.245 cm. The well depth for a 384 well MultiScreen plate is 1.2 cm. The maximum working volume of a 96 well plate is 300 ul. The maximum working volume for a 384 well plate is 100 ul.