Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

CTGR01TP1 Aervent CTGR Cartridge Filter 10 in. 0.2 µm Code 0

CTGR01TP1
1  Double Easy-Open bag
Purchase on Sigma-Aldrich

概述

Replacement Information
Description
Catalogue NumberCTGR01TP1
Trade Name
  • Aervent®
DescriptionAervent CTGR Cartridge Filter 10 in. 0.2 µm Code 0
References
Product Information
HS Code8421 39 90
Device ConfigurationCartridge
Maximum Differential Pressure, bar (psid)Forward: 5.5 bar (80 psid) @ 25 °C; 1.8 bar (25 psid) @ 80 °C. Reverse: 4.1 bar (60 psid), intermittent
Maximum Inlet Pressure, bar (psi)Forward - 5.5 bar (80 psi) @ 25 °C; 1.7 bar (25 psi) @ 80 °C; Reverse - 4.1 bar (60 psi), Intermittent
Cartridge CodeCode 0
Quality LevelMQ400
Applications
Biological Information
MediaAervent®
Sterilization150 (100 forward/50 reverse) SIP cycles of 30 min @ 145 °C
Bacterial Grow-ThroughRetains Brevundimonas diminuta liquid aerosol for 21 days at a minimum challenge of 10⁷ CFU/cm²
Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
WettabilityHydrophobic
Physicochemical Information
Pore Size0.2 µm
Bubble Point at 23 °C≥1100 mbar (16 psig) nitrogen with 70/30 % IPA/water
Gravimetric ExtractablesThe extractables level was equal to or less than 35 mg per 10-inch cartridge after 24 hours in a 70/30% IPA/water mixture at controlled room temperature.
HydroCorr≤0.75 mL/min @ 2.6 bar (38 psig) per 10 in cartridge
Nitrogen Diffusion at 23 °C≤24 mL/min @ 970 mbar (14 psig) in 70/30 % IPA/water
Non-Fiber ReleasingThis product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Virus Aerosol RetentionRated for aerosol retention of a total challenge of 108–1010 plaque forming units of ΦX-174 virus particles at 85 Nm3/h (50 SCFM) per cartridge.
USP Bacterial EndotoxinsAqueous extraction contains <0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
Dimensions
Cartridge Nominal Length10 in. (25 cm)
Diameter6.9 cm (2.7 in.)
Filtration Area0.65 m²
Device Size10 in.
Materials Information
Chemistry
  • Polytetrafluoroethylene (PTFE)
Device Material
  • Polypropylene
Seal MaterialSilicone (SI)
Support MaterialPolypropylene
Toxicological Information
Safety Information according to GHS
Safety Information
Product Usage Statements
Storage and Shipping Information
Packaging Information
Material Size1
Material PackageDouble Easy-Open bag
Transport Information
Supplemental Information
Specifications
Global Trade Item Number
产品目录编号 GTIN
CTGR01TP1 04053252346811