Chromolith® RP-18 endcapped

Chromolith Performance RP-18 endcapped HPLC columns are designed for rapid separations of more complex mixtures. The Chromolith® 3 mm internal-diameter column (length 100 mm) is an ideal alternative to conventional particulate columns with internal diameters of 4.6, 4 or 3 mm. Even difficult separations, which often take 15 to 30 minutes on particulate columns, typically take only 5 to 10 minutes on Chromolith® 3 mm i.d. 

Column Coupling

Chromolith® 3 mm i.d. columns can be easily coupled using the column coupler to form columns of 20 cm or longer as required. As shown in Tables 1 and 2, this results in very high peak resolution at moderate pressure with flow rates between 1 and 1.5 mL/min.

Chromolith® Performance RP-18e 100-3 mm

Column Chromolith® Performance RP-18e 100-3 mm
Mobile Phase Acetonitrile / buffer pH 1.8 (gradient)
Flow rate 2.0 mL/min
Pressure 92 bar
Detection UV 254 nm
Temp. 30°C
Injection volume 1 μL
Sample 1. - 2. By-products
3. Levothyroxine
4. - 9. By-products>
Chromolith® Performance RP-18e 100-3 mm
Two coupled Chromolith® Performance RP-18e 100-3 mm

Column Two coupled Chromolith® Performance RP-18 endcapped 100-3 mm
Mobile Phase Acetonitrile / buffer pH 1.8 (gradient)
Flow rate 1.5 mL/min
Pressure 140 bar
Detection UV 254 nm
Temp. 30°C
Injection volume 1 μL
Sample 1. - 2. By-products
3. Levothyroxine
4. - 9. By-products
Two coupled Chromolith® Performance RP-18 endcapped 100-3 mm

Excellent Column Efficiency and Peak Resolution

Table 3 depicts a typical fast separation of four compounds in less than two minutes using a Chromolith® 4.6 mm i.d. column at a flow rate of 4 mL/min. The second example (Table 4) shows the same separation on a Chromolith® 3 mm i.d. column. Both chromatograms exhibit excellent column efficiency and peak resolution, however the 3 mm i.d. column demonstrates improved sensitivity at just 1.7 mL/min, thus saving 57% of solvents.

Chromolith® Performance RP-18e 100-4.6 mm

Column Chromolith® Performance RP-18 endcapped 100-4.6 mm
Mobile Phase Acetonitrile / water 40/60
Flow Rate 4.0 mL/min
Pressure 137 bar
Detection UV 254 nm
Temp. Ambient
Injection Volume 1 μL
Sample

1. Biphenyl-4.4 ’ -ol
2. Biphenyl-2.2 ’ -ol
3. Biphenyl-4-ol
4. Biphenyl-2-ol

Chromolith® Performance RP-18 endcapped 100-4.6 mm
Chromolith® Performance RP-18e 100-3 mm

Column Chromolith® Performance RP-18e 100-3 mm
Mobile Phase Acetonitrile / water 40/60
Flow Rate 1.7 mL/min
Pressure 100 bar
Detection UV 254 nm
2.4 μL flow cell * 
Temp. Ambient
Injection Volume 1 μL *
Sample 1. Biphenyl-4.4 ' -ol
2. Biphenyl-2.2 ' -ol
3. Biphenyl-4-ol
4. Biphenyl-2-ol
Chromolith® Performance RP-18e 100-3 mm

* For optimum results with 3 mm i.d. columns, extra-column volume must be small.

Chromolith® RP-18 Endcapped 2 mm and 3mm Columns

Product
Internal Diameter
Ordering Number
Chromolith® Performance RP-18 endcapped 100 x 2 mm
100 x 3 mm
152006
152001
Chromolith® Flash RP-18 endcapped 25 x 2 mm
25 x 3 mm
152014
152003
Chromolith® FastGradient RP-18 endcapped 50 x 2 mm
50 x 3 mm
152007
152002
 
HPLC Application Collections