Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

114560 COD Cell Test

Overview

Replacement Information

Products

Catalogue NumberPackaging Qty/Pack
1.14560.0001 EPS box 25 tests
Description
Catalogue Number114560
References
Product Information
HS Code3822 19 90
Quality LevelMQ100
Applications
Biological Information
Physicochemical Information
Density1.81 g/cm3 (20 °C)
pH value<1 (H₂O, 20 °C)
Dimensions
Materials Information
Toxicological Information
Safety Information according to GHS
Hazard Pictogram(s) Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Statement(s)H290: May be corrosive to metals.
H311: Toxic in contact with skin.
H314: Causes severe skin burns and eye damage.
H373: May cause damage to organs through prolonged or repeated exposure.
H410: Very toxic to aquatic life with long lasting effects.
Precautionary Statement(s)P234: Keep only in original packaging.
P273: Avoid release to the environment.
P280: Wear protective gloves/ protective clothing/ eye protection/ face protection/ hearing protection.
P303 + P361 + P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P314: Get medical advice/ attention if you feel unwell.
Signal WordDanger
Storage class6.1D Non-combustible, acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
WGKWGK 3 highly hazardous to water
Safety Information
Product Usage Statements
Storage and Shipping Information
StorageStore at +15°C to +25°C.
Packaging Information
Transport Information
Declaration (railroad and road) ADR, RIDUN 3316 Chemie-Testsatz, 9, II
Declaration (transport by air) IATA-DGRUN 3316 CHEMICAL KIT, 9, II
Declaration (transport by sea) IMDG-CodeUN 3316 CHEMICAL KIT, 9, II
Supplemental Information
Specifications
Global Trade Item Number
Catalogue Number GTIN
1.14560.0001 04022536155807

Documentation

COD Cell Test SDS

Title

Safety Data Sheet (SDS) 

COD Cell Test Certificates of Analysis

Product Number PackagingSpecificationLot Number
1.14560.0001 EPS boxPDF Specification Document

Certificates

Title
114560 - Certificate of Quality - Spectroquant COD Cell Test / CSB-Küvettentest / Test en cubetas DQO

Brochure

Title
Undisputed Accuracy for Your Quantitative Results

Technical Info

Title
COD Comparison Table 2017
COD Spectroquant Comparison table 1999
COD Spectroquant Method 1999
COD Spectroquant Method 2017
COD Spectroquant Test Kits Certificate Letter USEPA 2017C
COD Spectroquant WW Letter USEPA 1999
ISO conformity of COD Cell Tests
Programming data for Spectrophotometer and Spectroquant Test Kits
USEPA-approved Spectroquant®methods

User Guides

Title
Analytical Procedures and Appendices Spectroquant Prove 300
Analytical Procedures and Appendices Spectroquant®Prove 600
Manual Spectroquant NOVA 30
Manual Spectroquant®Prove Connect to Dashboard - English
Manual Spectroquant®Prove Connect to LIMS - English
Quick Guide Spectroquant Photometer NOVA 60A (EN, DE, FR, ES, IT)
User Guide (IFU) - 1.14560

Instructions for Use

Title
Spectroquant®Prove Quick Guide - Chinese Simplified

Related Products & Applications

Alternative Products

Catalogue Number Description
109772 COD Cell Test (Hg-free)
114540 COD Cell Test
118750 COD Cell Test for photometers of other manufacturers

Related Products

Catalogue Number Description
114540 COD Cell Test

Accessories (Primary)

Catalogue Number Description
110079 Chloride Test
114695 CombiCheck 50
171200 Thermoreactor
171201 Thermoreactor
171202 Thermoreactor

Accessories (Secondary)

Catalogue Number Description
114695 CombiCheck 50

Related Products By: Application Facete

Related Products By: Brand Facete

Categories

Analytics and Sample Preparation > Test Kits and Photometric Methods > Instrumental Test Systems for Quantitative Analyses > Photometric Measurements, Spectroquant® System > USEPA
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Boiler Water / Cooling Water > COD
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Waste Water > COD
Analytics and Sample Preparation > Test Kits and Photometric Methods > Instrumental Test Systems for Quantitative Analyses > Photometric Measurements, Spectroquant® System > Spectroquant® Tests
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Environment > COD
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Groundwater, Surface Water > COD
Analytics and Sample Preparation > Test Kits and Photometric Methods > Base Parameters from A to Z > COD
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Construction Material > COD
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Aquaristics > COD
Analytics and Sample Preparation > Test Kits and Photometric Methods > Areas of Application > Drinking Water > COD