Millipore Sigma Vibrant Logo

MultiScreen®HTS Vacuum Manifold

For vacuum filtration of 96 and 384 samples

Related Resources

Overview

Specifications

Ordering Information

Go
MultiScreenHTS Vacuum Manifold for use with 96- and 384-well MultiScreenHTS filter plates as well as MultiScreen Solvinert and Solvinert Deep Well filter platesClear Sorting & Filtering Show Filter
Catalogue NumberDescriptionComponentsPack Size
MSVMHTS00MultiScreenHTS Vacuum Manifold
  • includes manifold base, standard collar, gaskets, gasket inserts, all tubing, valves, and pressure gauge
1 Show Pricing & Availability

Back To Top

MultiScreen Vacuum Manifold for use with standard MultiScreen (classic) filter platesClear Sorting & Filtering Show Filter
Catalogue NumberDescriptionComponentsPack Size
MAVM0960RMultiScreen™ Vacuum Manifold 96-well
  • includes manifold base, standard ring with gaskets, support grid, all tubing, valves and pressure gauge
1 Show Pricing & Availability

Back To Top

Vacuum Pump - AccessoriesClear Sorting & Filtering Show Filter
Catalogue NumberDescriptionPack Size
SLFG05010Millex-FG, 0.20 µm, hydrophobic PTFE, 50 mm 10 Show Pricing & Availability
WP6110060Chemical Duty Pump, 100 V/50–60 Hz 1 Show Pricing & Availability
WP6111560Chemical Duty Pump, 115 V/60 Hz 1 Show Pricing & Availability
WP6122050Chemical Duty Pump, 220 V/50 Hz 1 Show Pricing & Availability

Back To Top

Collection PlatesClear Sorting & Filtering Show Filter
Catalogue NumberDescriptionSterilityPack Size
MSCPNPS0096-well Collection Plate Non-Sterile 100 Show Pricing & Availability
MSCPNPP0096-well Collection Plate Non-Sterile 100 Show Pricing & Availability
MSCPNUV4096-well Collection Plate Non-Sterile 40 Show Pricing & Availability
MDCPN2M5096 well Collection Plate Non-Sterile 50 Show Pricing & Availability

Back To Top

Sealing TapeClear Sorting & Filtering Show Filter
Catalogue NumberDescriptionSterilityPack Size
MATAHCL00MultiScreen Sealing Tape, clear, non-sterile Non-Sterile 100 Show Pricing & Availability

Back To Top

Documentation

References

Reference overviewApplication
Method for Simultaneous Measurement of Antibodies to 23 Pneumococcal Capsular Polysaccharides
Raymond Biagini, Sonela Schlottmann, Deborah Sammons, Jerome Smith, John Snawder, Cynthia Striley, Barbara MacKenzie, and David Weisssman
Clinical and Diagnostic Laboratory Immunology September 2003, p 744-750, Vol. 10, No. 5  2003

A non-radiolabelled ferriprotoporphyrin IX biomineralisation inhibition test for the high throughput screening of antimalarial compounds.
E. Deharo, R. N. Garcia, P. Oporto, A. Gimenez, M. Sauvain, V. Jullian and H. Ginsburg
Experimental Parasitology 100 (4): 252-256  2002

High-Throughput Microplate Format for Producing and Screening Riboprobes from Bacterial Cells
Matthews, P.D. and Wurtzel, E.T.
BioTechniques. 18: 6, 1000 – 1004  1995

Nucleic Acid Purification and Concentration
Use of Multiscreen plates for the preparation of bacterial DNA suitable for PCR
Reek FH, Smits MA, Kamp EM, Smith HE
Biotechniques. 1995 Aug;19(2):282-5  1995

PCR

FAQ

QuestionAnswer
What plates are compatible with the MultiScreen manifold?In general, all manufacturers' plates fit the vacuum manifold.
I’m not getting good vacuum while using the MultiScreen vacuum manifold, what can I do?Press down on the MultiScreen plate to form a good seal with the manifold. (This is normal for the low vacuum used). Make sure all wells of the filter plate are either “wet” or sealed with adhesive tape. Check all tubing connections to make sure they are tight. See the MultiScreen Vacuum manifold operators guide for more detailed troubleshooting information.
What plates can be used with the MultiScreen HTS manifold (Catalogue number MSVMHTS00)?All MultiScreen HTS platform filter plates, Solvinert and Solvinert Deep Well plates can be used with the HTS manifold.
Can the classic MultiScreen plates be run on the HTS manifold?Only in filter to waste mode. The HTS plates should be used with the HTS manifold for the most benefit.
Can the MultiScreen HTS manifold be used with Millipore's genomics application plates (plamid prep, pcr cleanup, sequence reaction clean up)?Filter to waste modes work, but not filtrate collection, so using the clearing plate with the plamid plate will not work. Millipore's genomics plates have not been validated on the HTS manifold. Please contact technical service for more information at 1-800-645-5476.
If using the MultiScreen HTS manifold, when do I have to use the droplet trap array?The droplet trap array should be used when filtering a 384 well plate to waste.
If the deep well collar sold with the MultiScreen HTS manifold or is it sold seperately?The deep well collar is sold as an accessory to the MultiScreen HTS manifold; it does not come with the manifold. The catalogue number is MSVMHTS0D.
When using the MultiScreen HTS manifold, can I filter to waste when using a shallow well plate?Yes. The classic grid should be in place for removeable underdrain HTS plates or the collar gasket frame should be in place for Solvinert plates.
When using the MultiScreen HTS vacuum manifold, can I filter to waste when using a deep well plate?Yes. The deep well plate should be placed on top of the manifold collar with the clear gasket support installed.
When using the MultiScreen HTS manifold, how can I test to see if the manifold is properly installed and/or that I have enough vacuum for my application?The easiest way to test the manifold and/or set vacuum pressures is to put the collar on the base with nothing inside and place a collection (plastic bottom) plate on the top. You can now adjust the vacuum to the desired level.

Related Products & Applications

Product Families

Related Products By: Application Facete

Related Products By: Brand Facete

Categories

Life Science Research > Cell Culture and Systems > Cell Culture Flasks, Plates, & Slides > Multiwell Plates