Millipore Sigma Vibrant Logo

KVEPS006HB3 Opticap® Sterile XL 600 Millipore Express® SHR single layer 0.1 µm 9/16 in. HB/HB with Bell

View Products on Sigmaaldrich.com
KVEPS006HB3
3  Double Easy-Open bag
Prix en cours de récupération
Le prix n'a pas pu être récupéré
La quantité minimale doit être un multiple de
Maximum Quantity is
À la validation de la commande Plus d'informations
Vous avez sauvegardé ()
 
Demander le prix
Disponibilité limitée
Disponibilité limitée
En stock 
Interrompu(e)
Disponible en quantités limitées
Disponibilité à confirmer
    Pour le restant : Nous vous tiendrons informé
      Pour le restant : Nous vous tiendrons informé
      Nous vous tiendrons informé
      Contacter le Service Clients
      Contact Customer Service

       

      Contacter le Service Clients

      Aperçu

      Replacement Information
      Description
      Catalogue NumberKVEPS006HB3
      Trade Name
      • Millipore Express®
      DescriptionOpticap® Sterile XL 600 Millipore Express® SHR single layer 0.1 µm 9/16 in. HB/HB with Bell
      References
      Product Information
      Device ConfigurationCapsule
      Connections, Inlet/Outlet14 mm (9/16 in.) Hose Barb / 14 mm (9/16 in.) Hose Barb with Filling Bell
      Connections, Vent/Drain1/4 in. Hose Barb with double O-ring Seal
      Housing MaterialPolypropylene (PP)
      Maximum Differential Pressure, bar (psid)Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
      Maximum Inlet Pressure, bar (psi)6.9 bar (100 psi) intermittent @ 23 °C; 5.5 bar (80 psi) @ 23 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
      European Pressure Equipment DirectiveEMD Millipore Corporation® certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.
      Good Manufacturing PracticesThese products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
      Quality LevelMQ400
      Applications
      Biological Information
      Bacterial EndotoxinsAqueous extraction contains ≤0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) Test
      MediaMillipore Express® SHR
      SterilitySterile
      Sterilization3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
      Bacterial RetentionSamples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
      WettabilityHydrophilic
      Physicochemical Information
      Pore Size0.1 µm
      Inlet ConnectionHose Barb
      Outlet ConnectionHose Barb with Bell
      Air Diffusion at 23 °C≤5.8 mL/min @ 3.45 bar (50 psig) in water
      Bubble Point at 23 °C≥4000 mbar (58 psig) air with water
      Indirect Food AdditiveAll component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
      Maximum Inlet Pressure (psig)80 psig
      Maximum Differential Pressure80 psi (5.5 bar) continuous
      100 psi (6.9 bar) intermittent
      Maximum Inlet Temperature25 °C
      Non-Fiber ReleasingThis product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
      TOC/ConductivityAfter sterilization and a controlled water flush of 3.0 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
      USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
      Dimensions
      Cartridge Nominal Length6.5 in. (16.5 cm)
      Length16.5 cm (6.5 in.)
      Diameter5.6 cm (2.2 in.)
      Filtration Area1010 cm²
      Inlet to Outlet Width16.5 cm (6.5 in.)
      Inlet Connection Diameter9/16 in.
      Outlet Connection Diameter9/16 in.
      Materials Information
      Chemistry
      • Polyethersulfone (PES)
      Device Material
      • Polypropylene
      Seal MaterialSilicone (SI)
      Support MaterialPolypropylene
      Vent Cap MaterialPolypropylene (PP)
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Packaging Information
      Material Size3
      Material PackageDouble Easy-Open bag
      Transport Information
      Supplemental Information
      Specifications
      Oxidizable SubstancesWill meet the USP Oxidizable Substances Test requirements after a water flush of ≥1 L
      Global Trade Item Number
      Référence GTIN
      KVEPS006HB3 04053252641992

      Documentation

      Material Qualification Dossier

      TitreVersion
      6.0

      Operational Excellence Dossier

      Title

      Certificats de qualité

      Titre
      Opticap XL 600 Capsule Millipore Express SHR Membrane C2PB44660
      Opticap XL 600 Capsule Millipore Express SHR Membrane C9MA85885Y
      Opticap XL 600 Capsule Millipore Express SHR Membrane - C8BA42230Y
      Opticap XL 600 Capsule Millipore Express SHR Membrane C1PB85688
      Opticap XL 600 Capsule Millipore Express SHR Membrane C3AB79493
      Opticap XL 600 Capsule Millipore Express SHR Membrane C3CB04286
      Opticap XL 600 Capsule Millipore Express SHR Membrane C3JB44907
      Opticap XL 600 Capsule Millipore Express SHR Membrane C3SB90834
      Opticap XL 600 Capsule Millipore Express SHR Membrane C4DB14480
      Opticap XL 600 Capsule Millipore Express SHR Membrane C7MA68038

      Informations techniques

      Titre
      Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters
      Performance of High-Area Millipore Express®Cartridge Filters
      Scalable Process Filtration with Millipore Express® SHR 0.1 μm Filters

      Fiche technique

      Titre
      Millipore Express®SHR Hydrophilic Filters

      Manuels d'utilisation

      Titre
      User Guide - Filters with Millipore Express®Membrane