Millipore Sigma Vibrant Logo

SCT010 LuminiCell Tracker™ 540- Cell Labeling Kit

View Products on Sigmaaldrich.com
SCT010
1 Kit  
Retrieving price...
Price could not be retrieved
Minimum Quantity is a multiple of
Maximum Quantity is
Upon Order Completion More Information
You Saved ()
 
Request Pricing
Fulfillment and delivery delayed
Fulfillment and delivery delayed
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

       

      Contact Customer Service

      Overview

      Replacement Information
      Description
      Catalogue NumberSCT010
      DescriptionLuminiCell Tracker™ 540- Cell Labeling Kit
      OverviewAbsorbance Maximum: 423nm
      Emisson Maximum: 540nm

      Suggested Filters:
      Excitation: 405/458/488nm
      Emisson: 480-560nm
      Alternate Names
      • AIEDots Cell Tracker Dye
      • AIE Live Cell Fluorescent Dye
      • Fluorescent Cell Tracking Dye
      • Live Cell Fluorescent Nanoparticles
      Background InformationLong-term noninvasive cell tracking by fluorescent probes and quantum dots is of great importance to life science and biomedical engineering. Current methods used to fluorescently tag cells have been limited by short signal duration, high background auto-fluorescence or lengthy molecular cloning manipulations using GFP. LuminiCell Trackers™ are biocompatible organic fluorescent nanoparticles based on Aggregation Induced Emission technology, termed AIEDots. Aggregation induced emission (AIE) molecules emit fluorescence in an opposite manner than other common fluorophores (Quantum Dots, GFP). Propeller-shaped AIE fluorogens are non-emissive in solutions but become highly fluorescent upon aggregate formation. Due to these differences, LuminiCell Trackers™ have very high fluorescence intensities with minimal signal quenching allowing live cell fluorescent tagging for up to 10 days in vitro and 21 days in vivo. These properties make them optimal candidates for long interval live cell bioimaging experiments.

      The Luminicell Tracker™-540 Cell Labeling Kit contain green fluorescent AIEDot nanoparticles with TAT sequences. These nanoparticles can be used to fluorescently tag cells for long term cell tracking and tracing experiments.

      Features and Benefits

      ● Brighter: 10X brighter than other cell labeling technologies
      ● Photostable: 3X longer fluorescence without signal quenching
      ● Biocompatible: Non-toxic organic nanoparticles intended for biological applications
      ● Rapid Protocol: Easy-to-use protocol labels cells within 4 hours

      References

      1) Liu B, Tang BZ et al. Photostable fluorescent organic dots with aggregation-induced emission (AIE dots) for noninvasive long-term cell tracing. Sci Rep. 2013;3:1150.
      2) Kang Y et al. Long-Term Tracking Mesenchymal Stem Cell Differentiation with Photostable Fluorescent Nanoparticles. ACS Appl Mater Interfaces. 2016 May 18;8(19):11925-33.
      3) Tang, B. Aggregation-Induced Emission: Together We Shine, United We Soar! Chem Rev. 2015 Nov 11;115(21):11718-940.
      References
      Product Information
      HS Code3204 20 90
      Presentation20nM in 0.5ml PBS, pH 7.4
      Quality LevelMQ100
      Applications
      ApplicationBiocompatible organic fluorescent nanoparticles (AIEDots) that can be used to label cells for long term cell tracking and cell tracing in vitro and in vivo experiments.
      Key Applications
      • Cell Culture
      • Fluorescence
      Biological Information
      Physicochemical Information
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Quality AssuranceAbsorbance: 422+-5nm
      Concentration: 180-220nM
      Fluorescence: 540+/- 10nm
      Quantum Yield: ≥50%
      Brightness at 540nM: ≥3X10^7 M-1cm-1
      Cellular Assay: HeLa Cell Fluorescence
      Usage Statement
      • Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
      Storage and Shipping Information
      Storage ConditionsStore at -2-8°C upon receipt. Thaw at room temperature or in a water bath. Do not Freeze.

      Note: Some particulates may form as a result of nanoparticle aggregation during shipping. To get particulates back in solution, sonicate the vial containing LuminiCell Tracker™ three times for 1 min each before use.
      Packaging Information
      Material Size1 Kit
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      Catalogue Number GTIN
      SCT010 04054839235344

      Documentation

      LuminiCell Tracker™ 540- Cell Labeling Kit SDS

      Title

      Safety Data Sheet (SDS) 

      LuminiCell Tracker™ 540- Cell Labeling Kit Certificates of Analysis

      TitleLot Number
      LuminiCell Tracker™ 540- Cell Labeling Kit VP1705252
      LuminiCell Tracker™ 540- Cell Labeling Kit VP1910227
      LuminiCell Tracker™ 540- Cell Labeling Kit - VP1905291 VP1905291
      LuminiCell Tracker™ 540- Cell Labeling Kit - VP1908270 VP1908270

      References

      Reference overviewPub Med ID
      Extracellular Vesicles From Notch Activated Cardiac Mesenchymal Stem Cells Promote Myocyte Proliferation and Neovasculogenesis
      Wanling Xuan,1 Mahmood Khan,2 and Muhammad Ashraf
      Front Cell Dev Biol  8  11  2020

      Show Abstract
      32154243 32154243

      Data Sheet

      Title
      Data Sheet-SCT010

      Posters

      Title
      Cancer stem cell proliferation in human prostate and breast cancer cell lines
      Poster -Novel biocompatible fluorescent nanoparticle