Millipore Sigma Vibrant Logo

Amicon® Ultra-15 Centrifugal Filter Units

Provide both ultra-fast spin times and ultra-high recoveries

Panorama geral

Especificações

Informações para pedidos

Amicon® Ultra-15 Centrifugal Filter UnitsLimpar Classificação e Filtragem Show Filter
Número de catálogoDescriçãoNMWLTamanho da embalagem
UFC900308Amicon® Ultra-15 Centrifugal Filter Unit 3 KDa 8 Preço e disponibilidade
UFC900324Amicon Ultra-15 Centrifugal Filter Unit 3 KDa 24 Preço e disponibilidade
UFC900396Amicon® Ultra-15 Centrifugal Filter Unit 3 KDa 96 Preço e disponibilidade
UFC901008Amicon® Ultra-15 Centrifugal Filter Unit 10 KDa 8 Preço e disponibilidade
UFC901024Amicon® Ultra-15 Centrifugal Filter Unit 10 KDa 24 Preço e disponibilidade
UFC901096Amicon® Ultra-15 Centrifugal Filter Unit 10 KDa 96 Preço e disponibilidade
UFC903008Amicon® Ultra-15 Centrifugal Filter Unit 30 KDa 8 Preço e disponibilidade
UFC903024Amicon® Ultra-15 Centrifugal Filter Unit 30 KDa 24 Preço e disponibilidade
UFC903096Amicon® Ultra-15 Centrifugal Filter Unit 30 KDa 96 Preço e disponibilidade
UFC905008Amicon® Ultra-15 Centrifugal Filter Unit 50kDa 8 Preço e disponibilidade
UFC905024Amicon Ultra-15 Centrifugal Filter Unit 50 KDa 24 Preço e disponibilidade
UFC905096Amicon® Ultra-15 Centrifugal Filter Unit 50 KDa 96 Preço e disponibilidade
UFC910008Amicon Ultra-15 Centrifugal Filter Unit 100 KDa 8 Preço e disponibilidade
UFC910024Amicon® Ultra-15 Centrifugal Filter Unit 100 KDa 24 Preço e disponibilidade
UFC910096Amicon® Ultra-15 Centrifugal Filter Unit 100 KDa 96 Preço e disponibilidade

Amicon Ultra-15 Filter Units are assembled with centrifuge tubes and caps

Voltar ao início

Documentation

Referências

Visão geral das referênciasAplicação
Simultaneous reduction and alkylation of protein disulfides in a centrifugal ultrafiltration device prior to two-dimensional gel electrophoresis.
Smejkal GB, Li C, Robinson MH, Lazarev AV, Lawrence NP, Chernokalskaya E.
J Proteome Res. 2006 Apr;5(4):983-7.  2006

Protein Concentration
Ultrafiltration for proteomic sample preparation
E. Chernokalskaya, S. Gutierrez, A.M. Pit, J. T. Leonard
Electrophoresis, 25: 2461-2468  2004

Sample Prep

FAQ

PerguntaResposta
Amicon Ultra units are offered in what volumes?Amicon Ultra units are available in 0.5 mL, 4mL & 15ml volumes.
What is the recommended rotor for Amicon Ultra units?Any rotor capable of accommodating 22.7 cm in diameter and 124 mm length centrifuge tubes for the Amicon Ultra-4 and 35 mm in diameter and 121 mm in length for the Amicon Ultra-15 can be used for Amicon Ultra units.
How should I select the appropriate Molecular Weight Cutoff (MWCO) for Amicon Ultra?Select a Molecular Weight Cutoff that is 2x smaller that the Molecular Weight (MW) of the solute of interest.
Which membranes are available in Amicon Ultra units?Amicon Ultra units are only available with Ultracel regenerated cellulose material. This high recovery/low binding membrane is offered in 3,000, 10,000, 30,000, 50,000 & 100,000 MWCO.
Can the Amicon Ultra be spun to dryness?No, the Amicon Ultra has a built in deadstop.
Can the Amicon Ultra be used with nucleic acids?Yes, Amicon Ultra units have been evaluated for use with Genomic and PCR fragments. The 30 kDa MWCO provides the best balance between recovery and spin time. Protocols related to Genomic and PCR fragments can be found in the user guide.
What is the maximum sample volume for Amicon Ultra?
Amicon Ultra-4Amicon Ultra-15
Swinging Bucket4ml 15ml
Fixed Angle4ml(35 & 45 degree rotor angle)12ml(35 degree rotor angle)
3.5ml(23 degree rotor angle)
What is the maximum centrifugal force I can spin Amicon Ultra-4 & Amicon Ultra-15?
4ml15ml
Swinging Bucket4000 x g4000 x g
3500 x g for concentrated/viscous solutions
Fixed Angle(23, 35 &45 degrees)7500 x g5000 x g
What is the chemical compatibility of Amicon Ultra?Amicon Ultra units are intended for use with biological fluids and aqueous solutions. Please refer to the user guide, catalogue, or contact Technical Support.
Can Amicon Ultra units be sterilized with ethanol?Amicon Ultra is compatible with 70% Ethanol, but we have not done any studies to test for sterilization.