Millipore Sigma Vibrant Logo
Attention: We have moved. Merck Millipore products are no longer available for purchase on MerckMillipore.com.Learn More

KGEPG2TTT1 Opticap XLT20 Millipore Express SHF compatible Gamma 0,2 µm, raccords sanitaires TC 1-1/2" entrée/sortie

KGEPG2TTT1
1  Double sachet à ouverture facile
Purchase on Sigma-Aldrich

Aperçu

Replacement Information
Description
RéférenceKGEPG2TTT1
Nom de marque
  • Millipore Express®
DescriptionOpticap XLT20 Millipore Express SHF compatible Gamma 0,2 µm, raccords sanitaires TC 1-1/2" entrée/sortie
Références bibliographiques
Informations produit
Device ConfigurationCapsule
Raccords (Entrée/Sortie)Raccords sanitaires 1-1/2" pour tube 38 mm
Raccords (Évent/Purge)1/4 in. Hose Barb with double O-ring seal
SupportPolypropylène
Pression différentielle maximale (bar)Forward: 6.9 bar (100 psid) intermittent @ 25 °C; 5.5 bar (80 psid) @ 25 °C; 1.0 bar (15 psid) @ 80 °C. Reverse: 2.1 bar (30 psid) @ 25 °C, intermittent
Pression d'entrée maximale (bar)6.9 bar (100 psi) intermittent @ 25 °C; 5.5 bar (80 psi) @ 25 °C; 2.75 bar (40 psi) @ 60 °C; 1.0 bar (15 psi) @ 80 °C
Directive européenne Équipements sous pressionEMD Millipore Corporation® certifie que ce produit est conforme à la Directive européenne Equipements sous pression, 97/23/CE du 29 mai 1997. Ce produit a été classifié sous l'Article 3 § 3 de la Directive Récipients sous pression. Il a été conçu et fabriqué conformément aux règles de l'art en usage afin de garantir une utilisation sûre. Conformément à l'Article 3 § 3 de la Directive Equipements sous pression, ce produit ne porte pas le marquage CE.
Bonnes Pratiques de FabricationCes produits sont fabriqués dans un site de production qui adhère aux Good Manufacturing Practices (ou Bonnes Pratiques de Fabrication) de la FDA.
Port manomètre/en TéT-line
Quality LevelMQ400
Applications
Informations biologiques
Endotoxines bactériennesUn extrait aqueux contient ≤ 0,25 EU/ml déterminé selon le Test LAL
Milieux de cultureMillipore Express® SHF
StérilitéNon-sterile, Gamma compatible
StérilisationCompatible avec un rayonnement gamma de 45 kGy ; 3 cycles d'autoclave de 60 min à 123 °C ; non stérilisable à la vapeur en ligne
Rétention bactérienneLes échantillons ont retenu quantitativement un challenge deBrevundimonas diminuta à une concentration minimale de 1 x 10⁷ U.F.C./cm² en utilisant la méthode ASTM® F838.
MouillabilitéHydrophile
Informations physico-chimiques
Dimension de pores0.2 µm
Raccord d'entréeRaccord sanitaire
Raccord de sortieRaccord sanitaire
Diffusion d'air à 23 °C≤ 65,5 ml/min à 2,75 bar dans de l'eau
Point de bulle à 23 °C≥ 4000 mbar d'air, membrane mouillée à l'eau
Additif Alimentaire IndirectTous les matériaux répondent aux exigences de la FDA concernant les additifs alimentaires indirects citées dans le Code of Federal Regulations (21CFR177-182).
Pression d'entrée maximale (psig)80 psig
Maximum Differential Pressure80 psi (5.5 bar) continuous
100 psi (6.9 bar) intermittent
Température d'entrée maximale25 °C
Absence de relargage de fibresThis product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
C.O.T./ConductivitéAfter sterilization and a controlled water flush of 22 L, samples exhibited less than 500 ppb TOC per USP <643> and less than 1.3 µS/cm per USP <645> at 25 °C.
USP Bacterial EndotoxinsA sample aqueous extraction contains less than 0.25 EU/mL as determined by the Limulus Amebocyte Lysate (LAL) test.
Dimensions
Longueur nominale de la cartouche20 in. (50 cm)
Longueur62.5 cm (24.6 in.)
Diamètre10.7 cm (4.2 in.)
Surface de filtration1.14 m²
Largeur de l'entrée à la sortie15.2 cm (6.0 in.)
Taille du dispositif20 in.
Diamètre du raccord d'entrée1-1/2 in.
Diamètre du raccord de sortie1-1/2 in.
Informations sur les matériaux
Chimie
  • Polyethersulfone (PES)
Matériau du dispositif
  • Polypropylène stable au rayonnement gamma/Polysulfone
Matériaux des joints plats/toriquesSilicone
Matériau du supportPolyester
Matériau du bouchon de l'éventPolypropylène
Informations toxicologiques
Informations de sécurité selon le SGH
Informations sur la sécurité
Notifications sur l'utilisation du produit
Informations relatives au stockage et à l'expédition
Informations sur l'emballage
Quantité1
ConditionnementDouble sachet à ouverture facile
Informations sur le transport
Information complémentaire
Caractéristiques
Substances oxydablesRépond aux exigences du Test des substances oxydables selon l'USP après un rinçage à l'eau avec ≥ 3 l
Global Trade Item Number
Référence GTIN
KGEPG2TTT1 04053252395826

Documentation

Material Qualification Dossier

TitreVersion
1.0

Quality Management Dossier (Open Access)

Title

Operational Excellence Dossier

Title

Certificats de qualité

Titre
OPTICAP XLT 20 Capsule Millipore Express SHF membrane C3MB58416
OPTICAP XLT 20 Capsule Millipore Express SHR membrane C3MB58418
Opticap XLT 20 Capsule MIllipore Express SHF Membrane C0NB03949
Opticap XLT 20 Capsule Millipore Express SHF Membrane C7EA07385
Opticap XLT 20 Capsule Millipore Express SHF Membrane C7PA85218
Opticap XLT 20 Capsule Millipore Express SHF Membrane C0KB60647
Opticap XLT 20 Capsule Millipore Express SHF Membrane C0NB03369
Opticap XLT 20 Capsule Millipore Express SHF Membrane C0SB62032
Opticap XLT 20 Capsule Millipore Express SHF Membrane C1AB85739
Opticap XLT 20 Capsule Millipore Express SHF Membrane C1BB04423

Informations techniques

Titre
1X PBS (Phosphate Buffered Saline) Buffer Mixing Optimization
Autoclaving Guidelines for Opticap® XL and XLT Disposable Capsule Filters
Extended bacterial retention testing of Millipore Express® 0.2 μm filters in a continuous flow system
Scalable Process Filtration with Millipore Express® SHF 0.2 μm Filters
Scalable Process Filtration with Opticap® XL 150, 300 and 600 Capsules with Millipore Express® Membranes
Simplified, efficient sizing of sterilizing-grade normal flow filters for buffer solutions

Manuels d'utilisation

Titre
Opticap® XL Capsules and Opticap® XLT Capsules
User Guide - Filters with Millipore Express®Membrane