105636 HPTLC Gel de silice 60 DIOL F₂₅₄s

105636
Purchase on Sigma-Aldrich

Aperçu

Replacement Information

Products

RéférenceConditionnement Qté
1056360001 Boîte carton 25 units
Description
Référence105636
DescriptionHPTLC Silica gel 60 DIOL F₂₅₄s
AperçuOur NH2, CN and DIOL -modified silica sorbents are less polar then conventional silica phases, making them ideal for separating hydrophilic or charged substances. Our moderately polar cyano- and diol-modified silica plates can be used for both normal phase and reversed phase systems. An alternative to PEI cellulose, amino-modified NH2 plates provide weak basic ion exchange characteristics with special selectivity for charged compounds.
Références bibliographiques
Informations produit
Code SH3822 19 00
Quality LevelMQ100
Applications
ApplicationGlass HPTLC Silica gel 60 DIOL F₂₅₄s plates. Silica gel HPTLC plates size 20 x 10 cm, 25 sheets.
Informations biologiques
Informations physico-chimiques
Dimensions
Informations sur les matériaux
Informations toxicologiques
Informations de sécurité selon le SGH
Classe de stockage10 - 13 Autres liquides ou matières solides
Informations sur la sécurité
Notifications sur l'utilisation du produit
Informations relatives au stockage et à l'expédition
StockageConserver de +2°C à +30°C.
Informations sur l'emballage
Informations sur le transport
Information complémentaire
Caractéristiques
Specific surface area (according to BET; 5-Pt. measurement)480 - 540 m²/g
Pore volume (N₂-isotherm)0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution)5 - 7 µm
Layer thickness150 - 200 µm
Deviation of layer thickness per plate≤ 35 µm
Chromatographic testings:
A) Steroidtest, straight phase
hRf-values
- hydrocortisone, straight phase

4 - 8
- Reichstein S, straight phase11 - 18
- Methyltestosterone, straight phase27 - 36
B) Steroid test, reversed phase
- methyltestosterone, steroid test48 - 68
- Reichstein S, steroid test58 - 78
- hydrocortisone, steroid test68 - 88
Typical value determined on an activated plate (120°C, 15 min)
Eluent a) petroleum benzine 40-60°/acetone (80/20 v/v)
Eluent b) acetone/water (30/70 v/v)
Global Trade Item Number
Référence GTIN
1056360001 04022536713960

Documentation

HPTLC Gel de silice 60 DIOL F₂₅₄s FDS

Titre

Fiche de données de sécurité des matériaux (FDS) 

HPTLC Gel de silice 60 DIOL F₂₅₄s Certificats d'analyse

Référence ConditionnementSpécificationNuméro de lot
1056360001 Boîte cartonDocument de spécification PDF

Brochure

Titre
Fast and Precise. Thin Layer Chromatography by.

Informations techniques

Titre
Separation of Phenoxycarboxylic acids
Separation of anabolic compounds
Separation of anabolic compounds
Separation of derivatives of Urea
Separation of digital glycosides
Separation of herbicides/fungicides
Separation of ingredients in contraceptic pills
Separation of pesticides
Separation of progesterones
Separation of progesterones

Produits & Applications associés

Alternative Products

Référence Description
112668 HPTLC Gel de silice 60 DIOL F₂₅₄s

Related Products

Référence Description
112668 HPTLC Gel de silice 60 DIOL F₂₅₄s

Accessories (Primary)

Référence Description
112537 Lampe UV 254 nm

Produits associés classés par : Application Facete

Catégories

Analytics and Sample Preparation > Analytical Chromatography > Thin-Layer Chromatography (TLC) Products > High Performance Thin-Layer Chromatography Plates (HPTLC) > CN-, Diol-, NH2-modified Silica Plates (TLC and HPTLC)