Millipore Sigma Vibrant Logo

CB1044 Anti-OCLN Mouse mAb (1G7)

Overview

Replacement Information

Key Spec Table

Species ReactivityHostAntibody Type
HMMonoclonal Antibody

Pricing & Availability

Catalogue Number AvailabilityPackaging Qty/Pack Price Quantity
CB1044-100UG
Retrieving availability...
Limited Availability
Limited Availability
In Stock 
Discontinued
Limited Quantities Available
Availability to be confirmed
    Remaining : Will advise
      Remaining : Will advise
      Will advise
      Contact Customer Service
      Contact Customer Service

      100 μg
      Retrieving price...
      Price could not be retrieved
      Minimum Quantity is a multiple of
      Maximum Quantity is
      Upon Order Completion More Information
      You Saved ()
       
      Request Pricing
      Description
      OverviewRecognizes the ~55-60 kDa OCLN protein in HL-60 and HeLa cells.
      Catalogue NumberCB1044
      Brand Family Calbiochem®
      SynonymsAnti-Occludin
      Application Data
      Detection of human OCLN by immunoblotting. Sample: Whole cell lysate from HL-60 cells. Primary antibody: Anti-OCLN Mouse mAb (1G7) (Cat. No. CB1044) (1-5 µg/ml). Detection: chemiluminescence.

      Detection of human OCLN by immunocytochemistry. Sample: HeLa cells fixed in paraformaldehyde. Primary antibody: Anti-OCLN Mouse mAb (1G7) (Cat. No. CB1044) (10 µg/ml). Detection: fluorescence.
      References
      Product Information
      FormLiquid
      FormulationIn PBS, pH 7.2.
      Positive controlHL-60 cells, HeLa cells
      PreservativeNone
      Quality LevelMQ100
      Applications
      Key Applications Enzyme-Linked Immunosorbent Assay
      Immunoblotting (Western Blotting)
      Immunocytochemistry
      Application NotesELISA (see comments)
      Immunoblotting (1-5 µg/ml)
      Immunocytochemistry (10 µg/ml)
      Application CommentsFor ELISA, this antibody can be used as the capture antibody; recommended concentration is 10 ng/ml, 1 µg/well, 100 µl total volume. Variables associated with assay conditions will dictate the proper working dilution.
      Biological Information
      ImmunogenA recombinant polypeptide corresponding to amino acids of 423-523 human OCLN, expressed as a GST fusion protein
      Clone1G7
      HostMouse
      IsotypeIgG₁
      Species Reactivity
      • Human
      Antibody TypeMonoclonal Antibody
      Physicochemical Information
      Dimensions
      Materials Information
      Toxicological Information
      Safety Information according to GHS
      Safety Information
      Product Usage Statements
      Storage and Shipping Information
      Ship Code Blue Ice Only
      Toxicity Regulatory Review
      Storage -20°C
      Avoid freeze/thaw Avoid freeze/thaw
      Do not freeze Ok to freeze
      Special InstructionsFollowing initial thaw, aliquot and freeze (-20°C).
      Packaging Information
      Transport Information
      Supplemental Information
      Specifications
      Global Trade Item Number
      Catalogue Number GTIN
      CB1044-100UG 04055977228403

      Documentation

      Anti-OCLN Mouse mAb (1G7) SDS

      Title

      Safety Data Sheet (SDS) 

      Data Sheet

      Note that this data sheet is not lot-specific and is representative of the current specifications for this product. Please consult the vial label and the certificate of analysis for information on specific lots. Also note that shipping conditions may differ from storage conditions.

      Revision01-November-2010 RFH
      SynonymsAnti-Occludin
      ApplicationELISA (see comments)
      Immunoblotting (1-5 µg/ml)
      Immunocytochemistry (10 µg/ml)
      Application Data
      Detection of human OCLN by immunoblotting. Sample: Whole cell lysate from HL-60 cells. Primary antibody: Anti-OCLN Mouse mAb (1G7) (Cat. No. CB1044) (1-5 µg/ml). Detection: chemiluminescence.

      Detection of human OCLN by immunocytochemistry. Sample: HeLa cells fixed in paraformaldehyde. Primary antibody: Anti-OCLN Mouse mAb (1G7) (Cat. No. CB1044) (10 µg/ml). Detection: fluorescence.
      DescriptionPurified mouse monoclonal antibody. Recognizes the ~55-60 kDa OCLN protein.
      BackgroundOCLN is an integral membrane protein which is located at tight junctions. This protein may be involved in the formation and maintenance of the tight junction.
      HostMouse
      ImmunogenA recombinant polypeptide corresponding to amino acids of 423-523 human OCLN, expressed as a GST fusion protein
      Clone1G7
      IsotypeIgG₁
      Specieshuman
      Positive controlHL-60 cells, HeLa cells
      FormLiquid
      FormulationIn PBS, pH 7.2.
      PreservativeNone
      CommentsFor ELISA, this antibody can be used as the capture antibody; recommended concentration is 10 ng/ml, 1 µg/well, 100 µl total volume. Variables associated with assay conditions will dictate the proper working dilution.
      Storage Avoid freeze/thaw
      -20°C
      Do Not Freeze Ok to freeze
      Special InstructionsFollowing initial thaw, aliquot and freeze (-20°C).
      Toxicity Regulatory Review